5.7  Holdover
5.7.1

Configuration

The configuration of the holdover is easy and can be leaved untouched. However,
depending on the user needs and the boundaries for timing accuracy, the Time to
expired value should be adjusted to meet its specifications. In the Web GUI, this
can be adjusted by navigating to Configuration > Holdover.
OID
3.7210.x
3.7210.0
3.7210.1
3.7210.2
92
Name
holdover/cfg/xxx
Source Rank
<Integer>
Default: 0
Time to expire
<Integer>
Default:
79800
Force Trigger
<Enum>
0. STOP
1. START
2. NONE
Note:
HO in between timing source: Using the source rank the HO
can be placed between two timing sources. For example, the user
can use WR as primary timing source, HO as secondary and PTP
8265.1 as third one. This means that if WR fails, the device will enter in
HO until expiration and finally switch to PTP that might provide bet-
ter accuracy than an expired HO.
Value Type
Configuration for the Holdover if
available
Source rank of the holdover as timing
source. If leaved at zero it will be always
placed as the last timing source. Then the
user can allow to trigger the holdover
between W
Time until the holdover is considered out of
specification and expired (default ~24h)
Force to manually trigger the holdover
(START) or to expire it (STOP) without wait-
ing the expiration timer. NONE, does noth-
ing.
CHAPTER
Description
5
WR-Z16 User Manual Rev. v5.0