Safran WR-Z16 User Manual page 78

Table of Contents

Advertisement

5.2  General Timing Management
OID
3.13x0.3
3.13x0.4
3.13x0.5
3.13x0.6
The timing source can be expanded to show its advanced view by clicking on the
up-down icon under Advanced:
Figure 5-10:
The advanced view parameters are described below:
Table 5-1:
OID
3.13x1.xx
3.13x1.1
3.13x1.2
3.13x1.3
68
Name
Value
VCS Code <Integer>
Status
Disabled
OK
Warning
Critical
Message
<String>
Is Active
<Boolean>
Advanced info Time Source #1
Timing source info description
Name
Value
tsrc_info/x/Q
Clock Iden-
<String>
tity
Priority1
<Integer>
Default: 128
Priority2
<Integer>
Default: 128
Description
Code defined in the VSC table (
page 161
) that corresponds to a given condition
for this timing source.
Status that corresponds to the code defined in the
VSC table.
Message that corresponds to the code defined in
the VCS table.
Flag that indicates if this timing source has been
selected by the policy to actively discipline the vir-
tual clock of our device.
Description
Clock Quality of the x timing source.
Unique identity of PTP instance in the network.
Force BMCA decision using 1st priority (Lower values
take precedence).
Manually force BMCA to select a clockID when clock
quality is the same (Lower values take precedence).
CHAPTER
5
"VCS Code" on