APPENDIX
VSC
VSC-
21320
VSC-
20201
VSC-
22201
VSC-
21201
166
Device
HO
Status
CHANGEOVER
CRITICAL
CRITICAL
CHANGEOVER
Clock
Message
Class
Upstream device
187
in Free-Running
Locked:Upstream
187
GM in Free-run-
ning
Upstream GM in
187
Free-Running
Upstream GM in
187
Free-Running
Active
Description
Reference
BC: Hol-
The GM is not
dover
available any-
more in the net-
work. Instead
of staying
locked to a FR
upstream
device we fail
to our HO tim-
ing source if it
was READY
BC:
The BC clock is
WR/PTP @
locked but the
ifname
upstream GM
has fallen in
free-running
for different
reasons
Passive:
The GM is in
WR/PTP @
this network is
ifname
in Free-Run-
ning. This pass-
ive timing
source can
become active
only if no bet-
ter time source
is available.
BC: Hol-
GM announce
dover
itself to be now
in FR, if we
have an active
HO we should
exit through
this state and
fail to the HO
timing source
WR-Z16 User Manual