Device
HO
Message
Status
CRITICAL
Unlocked:
10MHz not
stable
WARNING
Locked: PPS
not present
WARNING
Locked: Time
of Day was
not set (NTP
error)
WARNING
Locked: Leap
seconds file
has expired
Clock
Active
Class
Reference
187
GM: Internal
Timeout in locking or
Oscillator
DAC blocked to the
limit. ~99% of the case
because 10MHz are not
stable or correct and
thus tmgr reach a
timeout count
6
GM: Front-
In case we are using an
panel
Atomic Clock as the
main reference and
someone has
unplugged the PPS
cable we might have
some problem on the
next reboot. PPS
defined as not man-
datory by user
6
GM: Front-
We have the same ref-
panel
erence on all the net-
work but the given
ToD is not be valid: Dur-
ing boot we can not
reach NTP server
(timeout or IP not con-
figured). The ToD used
is provided by release
ToD or last shutdown
ToD.
6
GM: Front-
Leapsec file in the GM
panel
device is expired or has
reach expiration while
the GM is running. This
means that the GM can
not guarantee the
UTC-TAI convertion
even if the currently
leap seconds used is
still valid. If
gm/cfg/leapsec_file_
ignore option is active,
this status will never
occur and will be noted
as VSC-10000.
Description
WR-Z16 User Manual