Operator Panel Error Codes - IBM eserver 630 6C4 Service Manual

Table of Contents

Advertisement

Operator Panel Error Codes

Attention:
corrected, go to "MAP 1540: Minimum Configuration" on page 101 unless otherwise
indicated in the tables.
If you replace FRUs and the problem is corrected, go to "MAP 0410: Repair Checkout"
in the RS/6000 Eserver pSeries Diagnostic Information for Multiple Bus Systems .
Table 3. Operator Panel Error Codes.
Error Code Description
0000 1111 At power on, failure of power-good
0000 1112 At power off, failure of power-good
0000 1113 While power on, failure of power-good
0000 1114 Operator panel and service processor
0000 2222 Operator panel not communicating with
0000 3333 SPCN communications error
0000 3334 I2C repeater error
0000 BBBB TOD battery malfunction
Eserver pSeries 630 Models 6C4 and 6E4 Service Guide
156
If you replace FRUs or perform an action and the problem is still not
signal from power supply.
signal from power supply.
signal from power supply.
have been reset after main power
disturbance.
service processor
Action/
Possible Failing FRU
1. CEC backplane
Location: U0.1-P1
2. CEC backplane power supply
Locations:
U0.1-V1
U0.1-V2
1. CEC backplane
Location: U0.1-P1
2. CEC backplane power supply
Locations:
U0.1-V1
U0.1-V2
1. CEC backplane
Location: U0.1-P1
2. CEC backplane power supply
Locations:
U0.1-V1
U0.1-V2
Information message
1. If system cannot be powered off,
reset the service processor (via the
pinhole reset or by disconnecting
then reconnecting power).
2. CEC backplane
Location: U0.1-P1
CEC backplane
Location: U0.1-P1
CEC backplane
Location: UO.1-P1
TOD battery
Location: U0.1-P1-V3