IBM eserver 630 6C4 Service Manual page 181

Table of Contents

Advertisement

Table 4. SPCN Error Codes (continued)
Error Code Description
1011 7660 System PCI fan 4 failure
1011 7661 System PCI fan 4 missing
1011 8400 VPD configuration problem
1011 8401 VPD access problem
1011 8402 VPD access problem
1011 8403 VPD level mismatch
1011 8404 Processor unit VPD mismatch
1011 8405 Processor unit VPD mismatch
1011 8406 Processor unit VPD mismatch
Action/
Possible Failing FRU
1. PCI fan 4
Location: U0.1-F4
2. CEC backplane
Location: U0.1-P1
1. PCI fan 4
Location: U0.1-F4
2. CEC backplane
Location: U0.1-P1
Ignore all location codes.
Go to "MAP 1540: Minimum
Configuration" on page 101 and run
minimum configuration.
Ignore all location codes.
Go to "MAP 1540: Minimum
Configuration" on page 101 and run
minimum configuration.
Ignore all location codes.
Go to "MAP 1540: Minimum
Configuration" on page 101 and run
minimum configuration.
Ignore all location codes.
Go to "MAP 1540: Minimum
Configuration" on page 101 and run
minimum configuration.
1. Processor card
Location: U0.1-P1-C1
2. CEC backplane
Location: U0.1-P1
1. Processor card
Location: U0.1-P1-C1
2. CEC backplane
Location: U0.1-P1
1. Processor card
Location: U0.1-P1-C2
2. CEC backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index
161

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver 630 6e4

Table of Contents