Table 3. Operator Panel Error Codes.
Error Code Description
0000 2222 Operator panel not communicating with
0000 3333 SPCN communications error
0000 3334 I2C repeater error
0000 BBBB TOD battery malfunction
168
Service Guide
If you replace FRUs or perform an action and the problem is still not
0000 1111 At power on, failure of power-good signal
from power supply.
0000 1112 At power off, failure of power-good signal
from power supply.
0000 1113 While power on, failure of power-good
signal from power supply.
0000 1114 Operator panel and service processor
have been reset after main power
disturbance.
service processor
Action/
Possible Failing FRU
1. Primary I/O backplane
Location: U0.1-P1
2. Primary I/O power supply
Locations:
U0.1-V1
U0.1-V2
1. Primary I/O backplane
Location: U0.1-P1
2. Primary I/O power supply
Locations:
U0.1-V1
U0.1-V2
1. Primary I/O backplane
Location: U0.1-P1
2. Primary I/O power supply
Locations:
U0.1-V1
U0.1-V2
Information message
1. If system cannot be powered
off, reset the service processor
(via the pinhole reset or by
disconnecting then
reconnecting power).
2. Primary I/O backplane
Location: U0.1-P1
Primary I/O backplane
Location: U0.1-P1
Primary I/O backplane
Location: UO.1-P1
TOD battery
Location: U0.1-P1-V3