Operator Information Panel - IBM eServer xSeries 235 Installation Manual

Table of Contents

Advertisement

Fans 1 and 2 LEDs: These LEDs provide status information about rear fans 1 and
2. For additional information, see the section about the Light Path Diagnostics
feature in the Hardware Maintenance Manual and Troubleshooting Guide on the
IBM xSeries Documentation CD.
Ethernet link status LED: This LED is on the Ethernet connector. When this LED
is on, there is an active connection on the Ethernet port.
PCI-X slot attention LED: This green LED flashes approximately once per second
when it is on. This LED is visible from the rear of the server and from inside the
server. The meaning of the attention LED is defined by your operating system. For
an illustration showing this LED on the system board, see the Option Installation
Guide on the IBM xSeries Documentation CD. For additional information, see "LEDs
for Active PCI slots" in the Hardware Maintenance Manual and Troubleshooting
Guide on the IBM xSeries Documentation CD.
NMI button: The Non-Maskable Interrupt (NMI) button is for service use only.
DC power LED: This green LED provides status information about the power
supply. During typical operation, both the ac and dc power LEDs are on. For any
other combination of LEDs, see the Hardware Maintenance Manual and
Troubleshooting Guide on the IBM xSeries Documentation CD.
AC power LED: This green LED provides status information about the power
supply. During typical operation, both the ac and dc power LEDs are on. For any
other combination of LEDs, see the Hardware Maintenance Manual and
Troubleshooting Guide on the IBM xSeries Documentation CD.

Operator information panel

The following illustration shows the status LEDs on the operator information panel
on the front of the server.
Power-on
LED
Important: If the power-on LED is off, it does not mean there is no electrical
46
IBM xSeries 235 Type 8671: Installation Guide
POST-
Hard disk drive
complete LED
activity LED
OK
1
TX
RX
Ethernet transmit/
receive activity LED
current present in the server. The LED might be burned out. To remove
all electrical current from the server, you must unplug the server power
cords from the electrical outlets or from the uninterruptible power
device.
Power-on LED: When this green LED is on, power is present in the server.
When this LED flashes, the server is in Standby mode (the system operating
system is turned off and ac current is present). When this LED is off, the power
subsystem, the ac power, or an LED has failed.
Information
LED
System-
error LED

Advertisement

Table of Contents
loading

Table of Contents