Operator Panel Error Codes

Attention:
corrected, go to "MAP 1540: Minimum Configuration" on page 57 unless otherwise
indicated in the tables.
If you replace FRUs or perform an action and the problem is corrected, go to "MAP
410: Repair Checkout" in RS/6000 and Eserver pSeries Diagnostic Information for
Multiple Bus Systems .
Note: Do not shut down the system if the FRU was replaced by hot swap.
Table 4. Operator Panel Error Codes
Error Code
0000 1111
0000 1112
0000 1113
0000 1114
0000 2222
0000 3333
0000 3334
0000 BBBB
If you replace FRUs or perform an action and the problem is still not
Description
At power on, failure of power-good
signal from power supply
At power off, failure of power-good
signal from power supply
While power on, failure of
power-good signal from power supply
Operator panel and service processor
have been reset after main power
disturbance.
Operator panel not communicating
with service processor
SPCN communications error
I2C repeater error
TOD battery malfunction
Action/ Possible Failing FRU
1. System board
Location: P1
2. Power supply
Location: V1 or V2 or V3
1. System board
Location: P1
2. Power supply
Location: V1 or V2 or V3
1. System board
Location: P1
2. Power supply
Location: V1 or V2 or V3
Information message
1. If system cannot be powered off,
reset the service processor (by
activating the pinhole reset switch
or by disconnecting, then
reconnecting, power).
2. System board, Location: P1
System board, Location: P1
System board, Location: P1
Location: P1-V4
Chapter 5. Error Code to FRU Index