Scsi Ids And Bay Locations - IBM eserver 630 6C4 Service Manual

Table of Contents

Advertisement

SCSI IDs and Bay Locations

Note: The pSeries 630 Model 6C4 and Model 6E4 are pictured with their bezels
Index
1
2
3
4
5
6
7
Notes:
1. The SCSI bus IDs are the recommended values and indicate how the IDs are set
when the system is shipped from the factory. Field installations might not comply
with these recommendations.
2. Media bay location D02 is designed to house one of the following optional devices:
v Tape Drive
v DVD-RAM
v Diskette Drive
Any SCSI device used in media bay location D02 will need to be connected to a
PCI SCSI adapter. The PCI SCSI adapter should be connected into PCI slot 3 or 4.
removed to show the disk drive and disk drive bay locations.
Bay Location
D01
D02
D10
D11
D12
D13
Drive Name
Operator Panel
IDE CD-ROM (Default)
or DVD-RAM (Optional)
Tape Drive (Optional)
DVD-RAM (Optional)
Diskette Drive (Optional)
Disk Drive
Disk Drive
Disk Drive
Disk Drive
Chapter 1. Reference Information
SCSI ID
IDE (Non-SCSI)
SCSI ID 1
SCSI ID 0
SCSI ID 1
N/A
SCSI ID 8
SCSI ID 9
SCSI ID 10
SCSI ID 11
31