Table 5. Firmware Error Codes. (continued)
Error Code Description
20EE 0008 No configurable adapters were found in
20EE 0009 Unable to communicate with the service
20EE 000B The system was not able to find an
20EE 000C Description: Pointer to the operating system not found in non-volatile storage.
20EE 000E Unable to execute the open firmware
Eserver pSeries 630 Models 6C4 and 6E4 Service Guide
168
the system by the remote IPL menu in
the SMS utilities.
processor.
operating system boot record on the
devices listed in the boot list.
This can be caused by the wrong
devices being in the boot list, a problem
that prevents the system from
communicating with the device that
contains the boot record, or the boot
record being corrupted.
Action: Values normally found in non-volatile storage that point to the location of
an operating system were not found. This can happen for two reasons, either your
installed operating system does not support storing the values or some event
occurred that caused the system to lose non-volatile storage information (drainage
or replacement of the battery). If you are running AIX, this information can be
reconstructed by running the bootlist command specifying the device that the
operating system is installed on. Refer to your AIX documentation for the exact
syntax and usage of the bootlist command.
To boot the operating system so that the above-mentioned values can be
reconstructed, power off the system and power it on again. This should cause the
system to look for the operating system in the devices contained in the custom
boot list or in the default boot list, depending on the condition of the system. If this
is not successful, use the System Management Services Menus to modify the
boot sequence (also known as boot list) to include devices that are known to
contain a copy of the operating system. For example, select a hard disk known to
have a copy of the operating system as the first and only device in the boot
sequence (boot list) and attempt to boot again, replace the CEC backplane.
Location: U0.1-P1.
method.
Action/
Possible Failing FRU
This warning occurs when the remote
IPL menu in the SMS utilities cannot
locate any LAN adapters that are
supported by the remote IPL function. If
a supported device is installed:
1. Replace the adapter.
2. PCI riser card,
Location: U0.1-P2
Replace the CEC backplane
Location: U0.1-P1.
Go to "Boot Problems/Concerns" on
page 150.
1. Reboot the system.
2. Reflash the system with the latest
level of system firmware.
3. Call service support.