Table 6. Service Processor Error Codes. (continued)
Error Code Description
4B23 26F7 Description: 2-way processor card fault
4B23 26F8 Description: 1-way processor card fault
4B23 26FA Description: 2-way processor card fault
Eserver pSeries 630 Models 6C4 and 6E4 Service Guide
250
Action: This error code indicates that the processor repeat gard function has
deconfigured a processor. Do the following:
1. Go to the processor configuration/deconfiguration menu, located under the
system information menu in the service processor menus.
Look at the status of the processors. If any of the processors have a status of
"manually deconfigured", reconfigure the processor(s) and boot the system to
the SMS menus. Power down the system using the white power button and
look again at the status of the processors. If all of the processors are still
configured in the processor configuration/deconfiguration menu, the problem
has been resolved.
If any of the processors have a status of "deconfigured by the system", either
before or after the boot to the SMS menus, go to step 2.
2. Replace the processor card (on which the deconfigured processor resides)
specified by the location code.
Action: This error code indicates that the processor repeat gard function has
deconfigured a processor. Do the following:
1. Go to the processor configuration/deconfiguration menu, located under the
system information menu in the service processor menus.
Look at the status of the processors. If any of the processors have a status of
"manually deconfigured", reconfigure the processor(s) and boot the system to
the SMS menus. Power down the system using the white power button and
look again at the status of the processors. If all of the processors are still
configured in the processor configuration/deconfiguration menu, the problem
has been resolved.
If any of the processors have a status of "deconfigured by the system", either
before or after the boot to the SMS menus, go to step 2.
2. Replace the processor card (on which the deconfigured processor resides)
specified by the location code.
Action: This error code indicates that the processor repeat gard function has
deconfigured a processor. Do the following:
1. Go to the processor configuration/deconfiguration menu, located under the
system information menu in the service processor menus.
Look at the status of the processors. If any of the processors have a status of
"manually deconfigured", reconfigure the processor(s) and boot the system to
the SMS menus. Power down the system using the white power button and
look again at the status of the processors. If all of the processors are still
configured in the processor configuration/deconfiguration menu, the problem
has been resolved.
If any of the processors have a status of "deconfigured by the system", either
before or after the boot to the SMS menus, go to step 2.
2. Replace the processor card (on which the deconfigured processor resides)
specified by the location code.