IBM eserver 630 6C4 Service Manual page 232

Table of Contents

Advertisement

Table 6. Service Processor Error Codes. (continued)
Error Code Description
406C 001F Memory DIMM fault
406C 00B0 Bus controller failure
406C 00B1 Bus controller failure
406C 00B3 Processor/VPD problem detected
406C 00B4 Processor/VPD problem detected
406C 00B7 Insufficient hardware resources were
406C 00D1 Informational message
406C 0100 Memory extender 0 on processor card 1 Processor card,
406C 0101 Memory extender 2 on processor card 1 Processor card,
406C 0130 Memory extender 0 on processor card 2 Processor card,
406C 0131 Memory extender 2 on processor card 2 Processor card,
406C 0A03 Reboot message on VPD channel 3
406C 0A04 Reboot message on VPD channel 4
406C 0B00 I/O slot 0, I/O port 0 (problem outside
Eserver pSeries 630 Models 6C4 and 6E4 Service Guide
212
detected to continue IPL of the system
after processor subsystem testing and
initialization was completed
processor card 1. Reboot is necessary
for run-time array gard to take effect.
processor card 2. Reboot is necessary
for run-time array gard to take effect.
the CEC drawer)
Action/
Possible Failing FRU
Memory DIMM
Location: U0.1-P1-C2-M4
1. Check for system firmware updates
2. PCI riser card
Location: U0.1-P2
1. Check for system firmware updates
2. PCI riser card
Location: U0.1-P2
1. Check for system firmware updates
2. Processor card 1
Location: U0.1-P1-C1
1. Check for system firmware updates
2. Processor card 2
Location: U0.1-P1-C2
Go to "MAP 1540: Minimum
Configuration" on page 101.
Informational message
Location: U0.1-P1-C1
Location: U0.1-P1-C1
Location: U0.1-P1-C2
Location: U0.1-P1-C2
Reboot the system in slow mode. Run
diagnostics, then go to "MAP 0235:
System Array Self-Repair Problem
Resolution" in the RS/6000 Eserver
pSeries Diagnostic Information for
Multiple Bus Systems .
Reboot the system in slow mode. Run
diagnostics, then go to "MAP 0235:
System Array Self-Repair Problem
Resolution" in the RS/6000 Eserver
pSeries Diagnostic Information for
Multiple Bus Systems .
Go to "MAP 1540: Minimum
Configuration" on page 101.