IBM eserver 630 6C4 Service Manual page 282

Table of Contents

Advertisement

Table 9. Common Firmware Error Codes (continued)
Error Code Description
B1xx 4634 SPCN loop fault
B1xx 4644 Processor VPD fault
B1xx 4645 Non-processor VPD fault
B1xx 4646 General VPD fault
B1xx 4647 The machine type and model reported
B1xx 4648 CEC backplane VPD failure
B1xx 4649 Power supply VPD failure
B1xx 4650 A system processor failure has been
B1xx 4651 CPU VPD fault
B1xx 4660 Memory subsystem failure
B1xx 4661 Memory card VPD failure
B1xx 4662 Memory DIMM VPD failure
Eserver pSeries 630 Models 6C4 and 6E4 Service Guide
262
by the CEC hardware do not match the
machine type and model stored in the
VPD module on the operator panel.
detected by the service processor. All
system processors have been reset in
an attempt to recover operations.
Action/
Possible Failing FRU
1. Check SPCN cabling
2. Go to "MAP 1540: Minimum
Configuration" on page 101.
Ignore all location codes.
Go to "MAP 1540: Minimum
Configuration" on page 101 and run
CEC minimum configuration.
Ignore all location codes.
Go to "MAP 1540: Minimum
Configuration" on page 101 and run
CEC minimum configuration.
Ignore all location codes.
Go to "MAP 1540: Minimum
Configuration" on page 101 and run
CEC minimum configuration.
Replace the operator panel, location:
U0.1-L1. Do not swap the VPD module
from the old operator panel onto the
new operator panel; leave the new,
unprogrammed VPD module on the new
operator panel. Call service support for
instructions on reprogramming the
machine type, model, and system serial
number in the VPD module.
Ignore all location codes.
Go to "MAP 1540: Minimum
Configuration" on page 101 and run
CEC minimum configuration.
CEC power supply
Location: U0.1-V1, U0.1-V2
Information only. If the problem persists,
check the error logs for other fault
indications.
If no other fault indications are found,
go to "MAP 1540: Minimum
Configuration" on page 101.
Processor card
Location: U0.1-P1-C1, U0.1-P1-C2
Go to "MAP 1540: Minimum
Configuration" on page 101.
Go to "MAP 1540: Minimum
Configuration" on page 101.
Go to "MAP 1540: Minimum
Configuration" on page 101.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver 630 6e4

Table of Contents