Sharp SF-S55N Service Manual page 63

20-bin staple sorter
Table of Contents

Advertisement

E In-bin paper sensor error
Causes/Defective parts
Step
Cable
1
Check that the cable between the sorter
controller PWB and the bin unit control PWB has
been connected correctly.
Cable
2
Check that the cables of in-bin paper sensor
light emitting side (S3/S6) and light receiving
side (S4/S7) have been correctly connected to
the bin unit control PWB. (Connector J302)
Installation of
3
Check that the in-bin paper sensor light emitting
in-bin paper
side (S3/S6) and light receiving side (S4/S7)
sensor light
have been installed normally.
emitting side
(S3/S6) and
light receiving
side (S4/S7)
In-bin paper
4
Check whether normal state can be restored by
sensor light
replacing the in-bin paper sensor light emitting
emitting side
side (S3/S6) and light receiving side (S4/S7) and
(S3/S6) and
subsequently adjusting the sensitivity of in-bin
light receiving
paper sensor.
side (S4/S7)
Bin unit control
5
Check whether the normal state can be restored
PWB
by replacing the bin unit control PWB and
subsequently adjusting the sensitivity of in-bin
paper sensor.
Sorter controller
PWB
Checking
7−7
Results
Corrective action
NO
Connect correctly.
NO
Correctly connect.
NO
Correctly install. If the in-bin paper
sensor light emitting side (S3/S6)
or light receiving side (S4/S7) has
been re-installed, adjust the in-bin
paper sensor sensitivity.
YES
Replace the in-bin paper sensor
light emitting side (S3/S6) and
light receiving side (S4/S7), and
adjust the sensitivity of in-bin
paper sensor.
YES
Replace the bin unit control PWB,
and adjust the sensitivity of in-bin
paper sensor.
NO
Replace the sorter controller PWB,
and adjust the sensitivity of in-bin
paper sensor.
SF-S55N

Advertisement

Table of Contents
loading

Table of Contents