Enter/Exit Programming Mode
Code 11 Check Character Transmission
This feature enables/disables transmission of an optional Code 11 check character.
$CC1CT00(CR)
Code 11 Check Character Transmission = Don't Send
$CC1CT01(CR)
DEFAULT
Code 11 Check Character Transmission = Send
Code 11 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CC1LC00(CR)
DEFAULT
Code 11 Length Control = Variable Length
$CC1LC01(CR)
Code 11 Length Control = Fixed Length
QuickScan™ I QD24XX
148
Need help?
Do you have a question about the QuickScan I QD24 Series and is the answer not in the manual?