Aiming Duration Time

Specifies the frame of time the aiming pointer remains on after decoding a label, when in trigger single mode. The
range for this setting is from 1 to 255 seconds in 1-second increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.
3. Go to
page 76
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
Mode.
4. Scan the bar code: SELECT AIMING DURATION TIME SETTING.
5. Scan the appropriate three digits from the keypad in
was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not
save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See
Table 40. Aiming Duration Time Setting Examples
STEP
ACTION
1
Desired Setting
2
Pad leading zero(es)
3
4
Scan Three Characters From
5
Appendix D, Keypad
6
Product Reference Guide
Table 40
for some examples of how to set this feature.
1 Second
001
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT AIMING DURATION TIME SETTING
'0' , '0' and '1'
Scan ENTER/EXIT PROGRAMMING MODE
Appendix D,
Keypad, that represent the duration which
EXAMPLES
90 Sec. (1.5 min.)
180 Sec. (3 min.) 255 Seconds (4.25 min.)
090
'0' , '9' and '0'
'1' , '8' and '0'
Scanning Features
180
255
'2' , '5' and '5'
231