Plessey Set Length 2 - Datalogic QuickScan I QD24 Series Product Reference Manual

General purpose handheld area imager bar code reader
Hide thumbs Also See for QuickScan I QD24 Series:
Table of Contents

Advertisement

Plessey Set Length 2

This feature specifies one of the bar code lengths for
if in
Variable Length
Mode, or the second fixed length if in
check, data, and full-ASCII shift characters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Table 24
provides examples for setting Length 2. See
Table 24. Plessey Length 2 Setting Examples
STEP
ACTION
1
Desired Setting
2
3
Scan Two Characters From
4
Appendix D, Keypad
5
$CPLL2
Select Plessey Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
Product Reference Guide
00 (Ignore This
Length)
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT PLESSEY LENGTH 2 SETTING
'0' and '0'
Scan ENTER/EXIT PROGRAMMING MODE
DEFAULT
Plessey Length
Control. Length 2 is the maximum label length
Fixed Length
Mode. Length includes the bar code's
page 217
for detailed instructions on setting this feature.
EXAMPLES
07 Characters
'0' and '7'
~
50 = Length 2 is 50 Characters
Enter/Exit Programming Mode
15 Characters
50 Characters
'1' and '5'
'5' AND '0'
CANCEL