Gs1 Databar™ Expanded Length Control - Datalogic QuickScan I QD24 Series Product Reference Manual

General purpose handheld area imager bar code reader
Table of Contents

Advertisement

Enter/Exit Programming Mode
GS1 DataBar™ Expanded Length Control
This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar™ Expanded
symbology.
Variable Length:
For variable-length decoding, a minimum length may be set.
Fixed Length:
For fixed-length decoding, two different lengths may be set.
$CXBLC00(CR)
DEFAULT
GS1 DataBar™ Expanded Length Control = Variable
Length
$CXBLC01(CR)
GS1 DataBar™ Expanded Length Control = Fixed Length
QuickScan™ I QD24XX