Standard 2 of 5 Set Length 1

This feature specifies one of the bar code lengths for
label length if in
Variable Length
code's check and data characters. The length can be set from 1 to 50 characters.
Table 9
provides some examples for setting Length 1. See
feature.
Table 9. Standard 2 of 5 Length 1 Setting Examples
STEP
ACTION
1
Desired Setting
2
3
Scan Two Characters From
4
Appendix D, Keypad
5
$CS2L1
Select Standard 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
Product Reference Guide
Mode, or the first fixed length if in
01 Character
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING
'0' and '1'
Scan ENTER/EXIT PROGRAMMING MODE
DEFAULT
Standard 2 of 5 Length
Fixed Length
page 217
if you want detailed instructions on setting this
EXAMPLES
07 Characters
'0' and '7'
~
08 = Length 1 is 8 Characters
Enter/Exit Programming Mode
Control. Length 1 is the minimum
Mode. Length includes the bar
15 Characters
50 Characters
'1' and '5'
'5' AND '0'
CANCEL