Code 32 Feature Setting Exceptions

The following features are set for Code 32 by using these Code 39 settings:
"Code 39 Quiet Zones" on page 107
"Code 39 Length Control" on page 107
"Trioptic Code" on page 110

Code 32 Check Char Transmission

Enable this option to transmit the check character along with Code 32 bar code data.
DEFAULT
$CP3CT01(CR)
Code 32 Check Character Transmission = Send

Code 32 Start/Stop Character Transmission

This option enables/disables transmission of Code 32 start and stop characters
DEFAULT
$CP3SS01(CR)
Code 32 Start/Stop Character Transmission = Transmit
Product Reference Guide
Enter/Exit Programming Mode
$CP3CT00(CR)
Code 32 Check Character Transmission = Don't Send
.
$CP3SS00(CR)
Code 32 Start/Stop Character Transmission = Don't
Transmit