  • Page 1 ® QuickScan QD2100 Barcode Imager Product Reference Guide...
  • Page 2 Configuring the Interface KEYBOARD FEATURES AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding Select KBD-AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD-AT-NK AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 Set KEYBOARD w/Alternate Key WEDGE...
  • Page 3: Baud Rate

    Chapter 5 RS-232 ONLY Interface Introduction Use the programming barcodes in this chapter if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB interfaces are available in Chapter 6, RS-232/ USB-Com Interfaces RS-232 Standard Factory Settings...
  • Page 4 RS-232 ONLY Interface Baud Rate — continued ENTER/EXIT PROGRAMMING MODE DEFAULT Baud Rate = 9600 Baud Rate = 19,200 Baud Rate = 38,400 Baud Rate = 57,600 Baud Rate = 115,200 QuickScan® QD2100...
  • Page 5: Data Bits

    Data Bits Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data. ENTER/EXIT PROGRAMMING MODE 7 Data Bits DEFAULT 8 Data Bits Product Reference Guide...
  • Page 6: Stop Bits

    The number of stop bits selected (one or two) depends on the number the receiv- ing terminal is programmed to accommodate. Set the number of stop bits to match host device requirements. ENTER/EXIT PROGRAMMING MODE DEFAULT 1 Stop Bit 2 Stop Bits QuickScan® QD2100...
  • Page 7 Parity Parity This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. • Select None when no parity bit is required. •...
  • Page 8: Handshaking Control

    RTS/CTS Scan Control — RTS is asserted during transmissions. CTS gates transmis- sions and controls enable and disable state of scanner. ENTER/EXIT PROGRAMMING MODE DEFAULT Handshaking Control = RTS Handshaking Control = RTS/CTS Handshaking Control = RTS/XON/XOFF Handshaking Control = RTS On/CTS Handshaking Control = RTS/CTS Scan Control QuickScan® QD2100...
  • Page 9 Chapter 6 RS-232/USB-Com Interfaces Introduction The programming barcodes in this chapter allow modifications to the standard RS-232 and USB-Com interfaces. Standard Factory Settings Reference for a listing of standard factory settings. Appendix B, Standard Defaults Product Reference Guide...
  • Page 10: Intercharacter Delay

    Divide by 10 (and pad with leading zeroes to yield two-digits) Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT INTERCHARACTER DELAY SETTING Scan Two Characters From ‘0’ and ‘5’ ‘5’ and ‘0’ 0’ and ‘0’ ‘8’ and ‘5’ Appendix E, Keypad Scan ENTER/EXIT PROGRAMMING MODE QuickScan® QD2100...
  • Page 11 Intercharacter Delay Intercharacter Delay — cont. ENTER/EXIT PROGRAMMING MODE Intercharacter Delay = No Delay Select Intercharacter Delay Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 00 = No Intercharacter Delay DEFAULT...
  • Page 12: Beep On Ascii Bel

    This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command. ENTER/EXIT PROGRAMMING MODE Beep On Not On File = Disable DEFAULT Beep On Not On File = Enable QuickScan® QD2100...
  • Page 13: Ack Nak Options

    ACK NAK Options ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK proto- col. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Options are: •...
  • Page 14: Ack Character

    Hex equivalent 0x06 0x24 0x40 0x3E Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT ACK CHARACTER SETTING Scan Two Characters From ‘0’ and ‘6’ ‘2’ and ‘4’ ‘4’ and ‘0’ ‘3’ AND ‘E’ Appendix E, Keypad Scan ENTER/EXIT PROGRAMMING MODE QuickScan® QD2100...
  • Page 15 ACK NAK Options ACK Character — cont. ENTER/EXIT PROGRAMMING MODE Select ACK Character Setting 0x06 ‘ACK’ Character DEFAULT Product Reference Guide...
  • Page 16: Nak Character

    Hex equivalent 0x15 0x24 0x40 0x3E Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT ACK CHARACTER SETTING Scan Two Characters From ‘1’ and ‘5’ ‘2’ and ‘4’ ‘4’ and ‘0’ ‘3’ AND ‘E’ Appendix E, Keypad Scan ENTER/EXIT PROGRAMMING MODE QuickScan® QD2100...
  • Page 17 ACK NAK Options NAK Character — cont. ENTER/EXIT PROGRAMMING MODE Select NAK Character Setting 0x15 ‘NAK’ Character DEFAULT Product Reference Guide...
  • Page 18: Ack Nak Timeout Value

    15,000ms (1 sec.) Divide by 200 Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT ACK NAK TIMEOUT VALUE SETTING Scan Two Characters From ‘0’ and ‘1’ ‘0’ and ‘5’ ‘2’ and ‘6’ ‘7’ and ‘5’ Appendix E, Keypad Scan ENTER/EXIT PROGRAMMING MODE QuickScan® QD2100...
  • Page 19 ACK NAK Options ACK NAK Timeout Value — cont. ENTER/EXIT PROGRAMMING MODE Select ACK NAK Timeout Value Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 ACK NAK Timeout value is 200ms DEFAULT...
  • Page 20: Ack Nak Retry Count

    Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT ACK NAK RETRY COUNT SETTING Scan Three Characters From ‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘3’ ‘0’, ‘5’ and ‘4’ ‘2’, ‘5’ and ‘5’ Appendix E, Keypad Scan ENTER/EXIT PROGRAMMING MODE QuickScan® QD2100...
  • Page 21 ACK NAK Options ACK NAK Retry Count — cont. ENTER/EXIT PROGRAMMING MODE Select ACK NAK Retry Count Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 003 = 3 Retries DEFAULT...
  • Page 22: Ack Nak Error Handling

    • Process error as valid NAK character ENTER/EXIT PROGRAMMING MODE DEFAULT ACK NAK Error Handling = Ignore Errors Detected ACK NAK Error Handling = Process Error as Valid ACK Character ACK NAK Error Handling = Process Error as Valid NAK Character QuickScan® QD2100...
  • Page 23: Indicate Transmission Failure

    Indicate Transmission Failure Indicate Transmission Failure This option enables/disables the reader’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode. ENTER/EXIT PROGRAMMING MODE Indicate Transmission Failure = Disable Indication DEFAULT Indicate Transmission Failure = Enable Indication Product Reference Guide...
  • Page 24: Disable Character

    Hex equivalent 0x64 0x7D 0x44 0xFF Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT DISABLE CHARACTER VALUE SETTING Scan Two Characters From ‘6’ and ‘4’ ‘7’ and ‘D’ ‘4’ and ‘4’ ‘F’ AND ‘F’ Appendix E, Keypad Scan ENTER/EXIT PROGRAMMING MODE QuickScan® QD2100...
  • Page 25 Disable Character Disable Character — cont. ENTER/EXIT PROGRAMMING MODE Select Disable Character Setting 0x44 = Disable Character is ‘D’ DEFAULT Product Reference Guide...
  • Page 26: Enable Character

    Hex equivalent 0x65 0x7D 0x45 0xFF Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT DISABLE CHARACTER VALUE SETTING Scan Two Characters From ‘6’ and ‘5’ ‘7’ and ‘D’ ‘4’ and ‘5’ ‘F’ AND ‘F’ Appendix E, Keypad Scan ENTER/EXIT PROGRAMMING MODE QuickScan® QD2100...
  • Page 27 Enable Character Enable Character — cont. ENTER/EXIT PROGRAMMING MODE Select Enable Character Setting 0x45 = Enable Character is ‘E’ DEFAULT Product Reference Guide...
  • Page 28 RS-232/USB-Com Interfaces NOTES QuickScan® QD2100...
  • Page 29: Keyboard Interface

    Chapter 7 Keyboard Interface Introduction Use the programming barcodes in this chapter to select options for USB Keyboard and Wedge Interfaces. Standard Factory Settings Reference for a listing of standard factory settings. Appendix B, Standard Defaults Scancode Tables Information about control character emulation which applies to keyboard interfaces is listed in Appendix F, Scancode Tables Product Reference Guide...
  • Page 30: Country Mode

    Country Mode = U.S. Country Mode = Belgium Country Mode = Britain Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Croatia Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Czechoslovakia QuickScan® QD2100...
  • Page 31 Country Mode Country Mode — continued ENTER/EXIT PROGRAMMING MODE Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Denmark Country Mode = France Country Mode = Germany Supports only the interfaces listed in theCountry Mode feature description.
  • Page 32 Country Mode = Romania Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Slovakia Country Mode = Spain Country Mode = Sweden Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Switzerland QuickScan® QD2100...
  • Page 33: Caps Lock State

    Caps Lock State Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding keyboard is selected. ENTER/EXIT PROGRAMMING MODE DEFAULT Caps Lock State = Caps Lock OFF Caps Lock State = Caps Lock ON Caps Lock State = AUTO Caps Lock Enable...
  • Page 34: Send Control Characters

    0x80 to 0xFE are intended as an extended ASCII table (Microsoft Windows Codepage 1252 — see Microsoft Windows Codepage 1252 on page 306 ENTER/EXIT PROGRAMMING MODE DEFAULT Wedge Send Control Characters = 00 Wedge Send Control Characters = 01 Wedge Send Control Characters = 02 QuickScan® QD2100...
  • Page 35: Wedge Quiet Interval

    Wedge Quiet Interval Wedge Quiet Interval This option specifies the amount of time to look for keyboard activity before the read- er breaks the keyboard connection in order to transmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments. This feature applies ONLY to the Keyboard Wedge interface.
  • Page 36 ENTER/EXIT PROGRAMMING MODE Select Wedge Quiet Interval Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 10 = Quiet Interval of 100 ms DEFAULT QuickScan® QD2100...
  • Page 37 Intercharacter Delay Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. This feature applies ONLY to the Keyboard Wedge interface.
  • Page 38 Intercharacter Delay = No Delay Select Intercharacter Delay Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 00 = No Intercharacter Delay DEFAULT QuickScan® QD2100...
  • Page 39: Intercode Delay

    Intercode Delay Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. Follow these instructions to set this feature: 1. Determine the desired setting. 2.
  • Page 40 Intercode Delay — cont. ENTER/EXIT PROGRAMMING MODE Set Intercode Delay Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 00 = No Wedge Intercode Delay DEFAULT QuickScan® QD2100...
  • Page 41: Usb Keyboard Speed

    USB Keyboard Speed USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard. This feature applies ONLY to the USB Keyboard interface. NOTE ENTER/EXIT PROGRAMMING MODE DEFAULT USB Keyboard Speed = 1ms USB Keyboard Speed = 2ms USB Keyboard Speed = 3ms USB Keyboard Speed = 4ms USB Keyboard Speed = 5ms...
  • Page 42 Keyboard Interface USB Keyboard Speed — continued ENTER/EXIT PROGRAMMING MODE USB Keyboard Speed = 6ms USB Keyboard Speed = 7ms USB Keyboard Speed = 8ms USB Keyboard Speed = 9ms USB Keyboard Speed = 10ms QuickScan® QD2100...
  • Page 43: Standard Factory Settings

    Chapter 8 USB-OEM Interface Introduction Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter and Chapter 9, IBM 46XX to specifically configure for the USB-OEM interface. Other USB interfaces are Interface included in the approprite chapter for their host type.
  • Page 44 It may be necessary to switch device usage when connecting two readers/scanners of the same type to a POS system. NOTE ENTER/EXIT PROGRAMMING MODE USB-OEM Device Usage = Table Top Scanner DEFAULT USB-OEM Device Usage = Handheld Scanner QuickScan® QD2100...
  • Page 45: Ibm 46Xx Interface

    Chapter 9 IBM 46XX Interface Introduction Use the barcodes in this section to configure programmable features for available IBM 46XX interfaces. IBM Standard Factory Settings Reference for a listing of standard factory settings. Appendix B, Standard Defaults Product Reference Guide...
  • Page 46: Xx Number Of Host Resets

    46xx Number of Host Resets = 1 46xx Number of Host Resets = 2 46xx Number of Host Resets = 3 46xx Number of Host Resets = 4 46xx Number of Host Resets = 5 DEFAULT 46xx Number of Host Resets = 6 QuickScan® QD2100...
  • Page 47 46xx Number of Host Resets 46xx Number of Host Resets — cont. ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets = 7 46xx Number of Host Resets = 8 46xx Number of Host Resets = 9 46xx Number of Host Resets = 10 46xx Number of Host Resets = 11 46xx Number of Host Resets = 12 Product Reference Guide...
  • Page 48 IBM 46XX Interface 46xx Number of Host Resets — cont. ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets = 13 46xx Number of Host Resets = 14 46xx Number of Host Resets = 15 QuickScan® QD2100...
  • Page 49: Transmit Labels In Code 39 Format

    Transmit Labels in Code 39 Format Transmit Labels in Code 39 Format This feature enable/disables translation to Code 39 before transmitting label data to an IBM-46XX or a USB-OEM host. Only the symbology identifier is modified for the translation. The data is not converted to Code 39 or verified to be valid for Code 39. Options are: IBM Standard Format —...
  • Page 50 IBM 46XX Interface NOTES QuickScan® QD2100...
  • Page 51: Data Editing

    Chapter 10 Data Editing Data Editing Overview It is not recommended to use these features with IBM interfaces. CAUTION When a barcode is scanned, additional information can be sent to the host computer along with the barcode data. This combination of barcode data and supplementary user- defined data is called a “message string.”...
  • Page 52: Please Keep In Mind

    If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE 5. If less than the expected string of 20 characters are selected, scan the ENTER/EXIT bar- code to terminate the string. QuickScan® QD2100...
  • Page 53 Global Prefix/Suffix 6. Scan the ENTER/EXIT barcode once again to exit Programming Mode. 7. The resulting message string would appear as follows: Scanned barcode data:12345 Resulting message string output: $12345 This option sets up to 20 characters each from the set of ASCII characters or any hex val- ue from 00 to FF.
  • Page 54: Global Aim Id

    Code 93 Code 11 UPC-A and UPC-E labels are converted to EAN 13 when adding AIM IDs. ISBN (X with a 0 modifier character) Figure 5. AIM ID Prefix Label ID AIM ID Bar Code Data Label ID Suffix QuickScan® QD2100...
  • Page 55 Global AIM ID Global AIM ID — continued ENTER/EXIT PROGRAMMING MODE DEFAULT Global AIM ID = Disable Global AIM ID = Enable Product Reference Guide...
  • Page 56 The AIM ID for GS1-128 is a ]C1, ]C2 or ]C3. AIM IDs for other symbologies can be enabled/disabled independently as well. Contact Customer Support for assistance. ENTER/EXIT PROGRAMMING MODE GS1-128 AIM ID = Disable DEFAULT GS1-128 AIM ID = Enable QuickScan® QD2100...
  • Page 57 Label ID Label ID A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x01-0xFF), used to identify a barcode (symbology) type. It can be appended previ- ous to or following the transmitted barcode data depending upon how this option is en- abled.
  • Page 58 464600 4A0000 EAN8 P5 464600 4B0000 EAN8 P8 464600 2A0000 FOLLETT 2OF5 4F0000 4F0000 GTIN 470000 244100 GTIN2 473200 244200 GTIN5 473500 244300 GTIN8 473800 244400 I2OF5 690000 4E0000 ISBN 490000 400000 ISBT128 660000 660000 CODE32 410000 580000 QuickScan® QD2100...
  • Page 59 Label ID Symbology Default Label ID set Alternate Label ID set 730000 500000 UPCA 410000 430000 UPCA P2 410000 460000 UPCA P5 410000 470000 UPCA P8 410000 510000 UPCE 450000 440000 UPCE P2 450000 480000 UPCE P5 450000 490000 UPCE P8 450000 450000 Product Reference Guide...
  • Page 60 7. Scan the ENTER/EXIT barcode once again to exit Programming Mode. This completes the steps to configure a Label ID for a given symbology. Figure 6. Label ID Position Options Prefix Label ID Aim ID Bar Code Data Label ID Suffix QuickScan® QD2100...
  • Page 61 Label ID Label ID — continued Table 18. Label ID Examples STEP ACTION EXAMPLES Scan the ENTER/EXIT barcode (Scanner enters Programming Mode) Determine placement of the Label ID characters BEFORE or AFTER with regard to scanned data using Enable as Prefix Enable as Suffix Enable as Prefix Enable as Suffix...
  • Page 62: Label Id Control

    Label ID Transmission = Enable as Prefix Label ID Transmission = Enable as Suffix Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL QuickScan® QD2100...
  • Page 63: Label Id Symbology Selection

    Label ID Label ID — continued Label ID Symbology Selection This option selects the symbology for which a Label ID is to be configured. See Label ID for full instructions. on page 95 ENTER/EXIT PROGRAMMING MODE Set UPC-A Label ID Character(s) Set UPC-A/P2 Label ID Character(s) Set UPC-A/P5 Label ID Character(s) Set UPC-A/GS1-128 Label ID Character(s)
  • Page 64 95 ENTER/EXIT PROGRAMMING MODE Set UPC-E/P5 Label ID Character(s) Set UPC-E/GS1-128 Label ID Character(s) Set EAN 13 Label ID Character(s) Set EAN 13/P2 Label ID Character(s) Set EAN 13/P5 Label ID Character(s) Set EAN 13/GS1-128 Label ID Character(s) QuickScan® QD2100...
  • Page 65 Label ID Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured. See Label ID for full instructions. on page 95 ENTER/EXIT PROGRAMMING MODE Set EAN 8 Label ID Character(s) Set EAN 8/P2 Label ID Character(s) Set EAN 8/P5 Label ID Character(s) Set EAN 8/GS1-128 Label ID Character(s)
  • Page 66 ENTER/EXIT PROGRAMMING MODE Set GTIN/P5 Label ID Character(s) Set GTIN/GS1-128 Label ID Character(s) Set GS1 DataBar Omnidirectional Label ID Character(s) Set GS1 DataBar Expanded Label ID Character(s) Set GS1 DataBar Limited Label ID Character(s) Set Code 39 Label ID Character(s) QuickScan® QD2100...
  • Page 67 Label ID Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured. See Label ID for full instructions. on page 95 ENTER/EXIT PROGRAMMING MODE Set Code 32 Label ID Character(s) Set Code 128 Label ID Character(s) Set Concatinated ISBT 128 Label ID Character(s) Set GS1-128 Label ID Character(s)
  • Page 68 Label ID for full instructions. on page 95 ENTER/EXIT PROGRAMMING MODE Set Standard 2 of 5 Label ID Character(s) Set Code 4 Label ID Character(s) Set Code 5 Label ID Character(s) Set Follett 2 of 5 Label ID Character(s) QuickScan® QD2100...
  • Page 69: Case Conversion

    Case Conversion Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case. Case conversion affects ONLY scanned barcode data, and does not affect Label ID, Prefix, Suffix, or other appended data. NOTE ENTER/EXIT PROGRAMMING MODE DEFAULT Case Conversion = Disable (no case conversion)
  • Page 70: Character Conversion

    5. Scan the ENTER/EXIT barcode to exit Programming Mode. If less than the expected string of 16 characters are selected, scan the ENTER/EXIT barcode twice to accept the selections and exit Pro- gramming Mode. NOTE QuickScan® QD2100...
  • Page 71 Character Conversion Character Conversion — continued ENTER/EXIT PROGRAMMING MODE Configure Character Conversion 0xFFFFFFFFFFFFFFFF DEFAULT (No character conversion) Product Reference Guide...
  • Page 72 Data Editing NOTES QuickScan® QD2100...
  • Page 73 UPC-A • GS1-128 • UPC-E • Interleaved 2 of 5 (I 2 of 5) • EAN 13 (JAN 13) • Datalogic 2 of 5 • EAN 8 (JAN 8) • Codabar • GS1 DataBar Omnidirectional • Code 11 • GS1 DataBar Expanded •...
  • Page 74 DEFAULT UPC-A = Enable UPC-A Check Character Transmission Enable this option to transmit the check character along with UPC-A barcode data. ENTER/EXIT PROGRAMMING MODE UPC-A Check Character Transmission = Don’t Send DEFAULT UPC-A Check Character Transmission = Send QuickScan® QD2100...
  • Page 75 UPC-A UPC-A — cont. Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. ENTER/EXIT PROGRAMMING MODE DEFAULT UPC-A to EAN-13 = Don’t Expand UPC-A to EAN-13 = Expand UPC-A Number System Character Transmission This feature enables/disables transmission of the UPC-A number system character.
  • Page 76 EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label starting with the three characters '980'. ENTER/EXIT PROGRAMMING MODE In-Store Minimum Reads = 1 DEFAULT In-Store Minimum Reads = 2 In-Store Minimum Reads = 3 In-Store Minimum Reads = 4 QuickScan® QD2100...
  • Page 77 UPC-E UPC-E The following options apply to the UPC-E symbology. UPC-E Enable/Disable When disabled, the reader will not read UPC-E barcodes. ENTER/EXIT PROGRAMMING MODE UPC-E = Disable DEFAULT UPC-E = Enable UPC-E Check Character Transmission Enable this option to transmit the check character along with UPC-E barcode data. ENTER/EXIT PROGRAMMING MODE UPC-E Check Character Transmission = Don’t Send DEFAULT...
  • Page 78 UPC-E to EAN-13 = Don’t Expand UPC-E to EAN-13 = Expand Expand UPC-E to UPC-A Expands UPC-E data to the UPC-A data format. ENTER/EXIT PROGRAMMING MODE DEFAULT UPC-E to UPC-A = Don’t Expand UPC-E to UPC-A = Expand QuickScan® QD2100...
  • Page 79 UPC-E UPC-E — cont. UPC-E Number System Character Transmission This feature enables/disables transmission of the UPC-E system number character. ENTER/EXIT PROGRAMMING MODE UPC-E Number System Character = Do not transmit DEFAULT UPC-E Number System Character = Transmit Product Reference Guide...
  • Page 80 This feature specifies the minimum number of consecutive times a UPC-E label must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE UPC-E Minimum Reads = 1 DEFAULT UPC-E Minimum Reads = 2 UPC-E Minimum Reads = 3 UPC-E Minimum Reads = 4 QuickScan® QD2100...
  • Page 81: Gtin Formatting

    GTIN Formatting GTIN Formatting This feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN 13 labels into the GTIN 14-character format. If add-on information is present on the base label prior to the conver- sion taking place, the addon information will be appended to the con- verted GTIN label.
  • Page 82: Ean 13 Check Character Transmission

    EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 barcode data. ENTER/EXIT PROGRAMMING MODE EAN 13 Check Character Transmission = Don’t Send DEFAULT EAN 13 Check Character Transmission = Send QuickScan® QD2100...
  • Page 83 EAN 13 EAN 13 — cont. EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label. ENTER/EXIT PROGRAMMING MODE EAN-13 Flag 1 Char= Don’t transmit DEFAULT EAN-13 Flag 1 Char= Transmit Product Reference Guide...
  • Page 84: Ean-13 Isbn Conversion

    Symbologies EAN-13 ISBN Conversion This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels. ENTER/EXIT PROGRAMMING MODE DEFAULT EAN-13 ISBN Conversion = Disable EAN-13 ISBN Conversion = Convert to ISBN QuickScan® QD2100...
  • Page 85: Ean 13 Minimum Reads

    EAN 13 EAN 13 — cont. EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE DEFAULT EAN 13 Minimum Reads = 1 EAN 13 Minimum Reads = 2 EAN 13 Minimum Reads = 3 EAN 13 Minimum Reads = 4...
  • Page 86: Ean 8 Check Character Transmission

    EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 barcode data. ENTER/EXIT PROGRAMMING MODE EAN 8 Check Character Transmission = Don’t Send DEFAULT EAN 8 Check Character Transmission = Send QuickScan® QD2100...
  • Page 87 EAN 8 EAN 8 — cont. Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. ENTER/EXIT PROGRAMMING MODE DEFAULT Expand EAN 8 to EAN 13 = Disable Expand EAN 8 to EAN 13 = Enable Product Reference Guide...
  • Page 88: Code

    ENTER/EXIT PROGRAMMING MODE DEFAULT EAN 8 Minimum Reads = 1 EAN 8 Minimum Reads = 2 EAN 8 Minimum Reads = 3 EAN 8 Minimum Reads = 4 QuickScan® QD2100...
  • Page 89: Code

    UPC/EAN Global Settings UPC/EAN Global Settings This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description. UPC/EAN Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
  • Page 90 UPC/EAN Global Settings — cont. UPC/EAN Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE UPC/EAN Decoding Level = 1 DEFAULT UPC/EAN Decoding Level = 2 UPC/EAN Decoding Level = 3 UPC/EAN Decoding Level = 4 UPC/EAN Decoding Level = 5 QuickScan® QD2100...
  • Page 91: Upc/Ean Correlation

    UPC/EAN Global Settings UPC/EAN Global Settings — cont. UPC/EAN Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
  • Page 92: Upc/Ean Price Weight Check

    ENTER/EXIT PROGRAMMING MODE DEFAULT Price Weight Check = Disabled Price Weight Check = 4-digit price-weight check Price Weight Check = 5-digit price-weight check Price Weight Check = European 4-digit price-weight check Price Weight Check = European 5-digit price-weight check QuickScan® QD2100...
  • Page 93 UPC/EAN Global Settings UPC/EAN Global Settings — cont. UPC-A Minimum Reads This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE DEFAULT UPC-A Minimum Reads = 1 UPC-A Minimum Reads = 2 UPC-A Minimum Reads = 3 UPC-A Minimum Reads = 4...
  • Page 94: Optional Add-Ons

    NOTE Conditional add-on settings (if enabled) are considered by the reader before optional add-on settings. ENTER/EXIT PROGRAMMING MODE DEFAULT Optional Add-Ons = Disable P2 Optional Add-Ons = Enable P2 DEFAULT Optional Add-Ons = Disable P5 QuickScan® QD2100...
  • Page 95 Add-Ons Add-Ons — cont. Optional Add-ons — cont. ENTER/EXIT PROGRAMMING MODE Optional Add-Ons = Enable P5 DEFAULT Optional Add-Ons = Disable GS1-128 Optional Add-Ons = Enable GS1-128 Product Reference Guide...
  • Page 96: Optional Add-On Timer

    (Also see Optional GS1-128 Add-On Timer on page 137 ENTER/EXIT PROGRAMMING MODE Optional Add-on Timer = 10ms Optional Add-on Timer = 20ms Optional Add-on Timer = 30ms Optional Add-on Timer = 40ms Optional Add-on Timer = 50ms QuickScan® QD2100...
  • Page 97 Add-Ons Add-Ons — cont. Optional Add-On Timer — cont. ENTER/EXIT PROGRAMMING MODE Optional Add-on Timer = 60ms DEFAULT Optional Add-on Timer = 70ms Optional Add-on Timer = 100ms Optional Add-on Timer = 120ms Optional Add-on Timer = 140ms Optional Add-on Timer = 160ms Product Reference Guide...
  • Page 98 ENTER/EXIT PROGRAMMING MODE Optional Add-on Timer = 180ms Optional Add-on Timer = 200ms Optional Add-on Timer = 220ms Optional Add-on Timer = 240ms Optional Add-on Timer = 260ms Optional Add-on Timer = 280ms Optional Add-on Timer = 300ms QuickScan® QD2100...
  • Page 99: Optional Gs1-128 Add-On Timer

    Add-Ons Add-Ons — cont. Optional GS1-128 Add-On Timer This option sets the timer expiration value to read the additional part after reading the linear EAN/UPC part. For UPC/EAN add-ons other than those of this type, see Option- al Add-On Timer on page 134 ENTER/EXIT PROGRAMMING MODE DEFAULT Optional GS1-128 Add-On Timer = Disable...
  • Page 100 ENTER/EXIT PROGRAMMING MODE Optional GS1-128 Add-On Timer = 60ms Optional GS1-128 Add-On Timer = 70ms Optional GS1-128 Add-On Timer = 100ms Optional GS1-128 Add-On Timer = 120ms Optional GS1-128 Add-On Timer = 140ms Optional GS1-128 Add-On Timer = 160ms QuickScan® QD2100...
  • Page 101 Add-Ons Add-Ons — cont. Optional GS1-128 Add-On Timer — cont. ENTER/EXIT PROGRAMMING MODE Optional GS1-128 Add-On Timer = 180ms Optional GS1-128 Add-On Timer = 200ms Optional GS1-128 Add-On Timer = 220ms Optional GS1-128 Add-On Timer = 240ms Optional GS1-128 Add-On Timer = 260ms Optional GS1-128 Add-On Timer = 280ms Optional GS1-128 Add-On Timer = 300ms Product Reference Guide...
  • Page 102: P2 Add-Ons Minimum Reads

    ENTER/EXIT PROGRAMMING MODE P2 Add-Ons Minimum Reads = 1 DEFAULT P2 Add-Ons Minimum Reads = 2 P2 Add-Ons Minimum Reads = 3 P2 Add-Ons Minimum Reads = 4 QuickScan® QD2100...
  • Page 103: P5 Add-Ons Minimum Reads

    Add-Ons Add-Ons — cont. P5 Add-Ons Minimum Reads This feature specifies the minimum number of times a P5 add-on must be read before it is marked as valid and then combined with a base label. ENTER/EXIT PROGRAMMING MODE DEFAULT P5 Add-Ons Minimum Reads = 1 P5 Add-Ons Minimum Reads = 2 P5 Add-Ons Minimum Reads = 3 P5 Add-Ons Minimum Reads = 4...
  • Page 104: Gs1-128 Add-Ons Minimum Reads

    ENTER/EXIT PROGRAMMING MODE DEFAULT GS1-128 Add-Ons Minimum Reads = 1 GS1-128 Add-Ons Minimum Reads = 2 GS1-128 Add-Ons Minimum Reads = 3 GS1-128 Add-Ons Minimum Reads = 4 QuickScan® QD2100...
  • Page 105: Gs1 Databar Omnidirectional

    GS1 DataBar Omnidirectional GS1 DataBar Omnidirectional The following options apply to the GS1 DataBar Omnidirectional (formerly RSS-14) symbology. GS1 DataBar Omnidirectional Enable/Disable When disabled, the reader will not read GS1 DataBar Omnidirectional barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Omnidirectional = Disable GS1 DataBar Omnidirectional = Enable GS1 DataBar Omnidirectional GS1-128 Emulation When enabled, GS1 DataBar Omnidirectional barcodes will be translated to the GS1-...
  • Page 106: Gs1 Databar Omnidirectional Minimum Reads

    ENTER/EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Omnidirectional Minimum Reads = 1 GS1 DataBar Omnidirectional Minimum Reads = 2 GS1 DataBar Omnidirectional Minimum Reads = 3 GS1 DataBar Omnidirectional Minimum Reads = 4 QuickScan® QD2100...
  • Page 107: Gs1 Databar Expanded

    GS1 DataBar Expanded GS1 DataBar Expanded The following options apply to the GS1 DataBar Expanded (formerly RSS Expanded) symbology. GS1 DataBar Expanded Enable/Disable When disabled, the reader will not read GS1 DataBar Expanded barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Expanded = Disable GS1 DataBar Expanded = Enable GS1 DataBar Expanded GS1-128 Emulation When enabled, GS1 DataBar Expanded barcodes will be translated to the GS1-128 label...
  • Page 108: Gs1 Databar Expanded Minimum Reads

    ENTER/EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Expanded Minimum Reads = 1 GS1 DataBar Expanded Minimum Reads = 2 GS1 DataBar Expanded Minimum Reads = 3 GS1 DataBar Expanded Minimum Reads = 4 QuickScan® QD2100...
  • Page 109: Gs1 Databar Expanded Length Control

    GS1 DataBar Expanded GS1 DataBar Expanded — cont. GS1 DataBar Expanded Length Control This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar Expanded symbology. Variable Length — For variable-length decoding, a minimum length may be set. Fixed Length —...
  • Page 110: Gs1 Databar Expanded Set Length 1

    52 Characters 74 Characters Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT GS1 DataBar EXPANDED LENGTH 1SETTING Scan Two Characters From ‘0’ and ‘1’ ‘0’ and ‘7’ ‘5’ and ‘2’ ‘7’ AND ‘4’ Appendix E, Keypad Scan ENTER/EXIT PROGRAMMING MODE QuickScan® QD2100...
  • Page 111 GS1 DataBar Expanded GS1 DataBar Expanded — cont. GS1 DataBar Expanded Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select GS1 DataBar Expanded Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Character DEFAULT...
  • Page 112: Gs1 Databar Expanded Set Length 2

    74 Characters length) Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT GS1 DataBar EXPANDED LENGTH 2 SETTING Scan Two Characters From ‘0’ and ‘0’ ‘0’ and ‘7’ ‘5’ and ‘2’ ‘7’ and ‘4’ Appendix E, Keypad Scan ENTER/EXIT PROGRAMMING MODE QuickScan® QD2100...
  • Page 113 GS1 DataBar Expanded GS1 DataBar Expanded — cont. GS1 DataBar Expanded Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select GS1 DataBar Expanded Set Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 74 = Length 2 is 74 Characters DEFAULT...
  • Page 114: Gs1 Databar Limited

    GS1 DataBar Limited GS1-128 Emulation When enabled, GS1 DataBar Limited barcodes will be translated to the GS1-128 label data format. ENTER/EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Limited GS1-128 Emulation = Disable GS1 DataBar Limited GS1-128 Emulation = Enable QuickScan® QD2100...
  • Page 115: Gs1 Databar Limited Minimum Reads

    GS1 DataBar Limited GS1 DataBar Limited — cont. GS1 DataBar Limited Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Limited Minimum Reads = 1 GS1 DataBar Limited Minimum Reads = 2...
  • Page 116: Code 39 Enable/Disable

    Symbologies Code 39 The following options apply to the Code 39 symbology. Code 39 Enable/Disable When disabled, the reader will not read Code 39 barcodes. ENTER/EXIT PROGRAMMING MODE Code 39 = Disable DEFAULT Code 39 = Enable QuickScan® QD2100...
  • Page 117: Code 39 Check Character Calculation

    Code 39 Code 39 — cont. Code 39 Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Code 39 check character. When disabled, any check character in the label is treated as a data character. ENTER/EXIT PROGRAMMING MODE Code 39 Check Character Calculation = Don’t Calculate DEFAULT...
  • Page 118: Code 39 Check Character Transmission

    Code 39 Check Character Transmission = Send Code 39 Start/Stop Character Transmission Enable this option to enable/disable transmission of Code 39 start and stop characters. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 39 Start/Stop Character Transmission = Don’t Transmit Code 39 Start/Stop Character Transmission = Transmit QuickScan® QD2100...
  • Page 119 Code 39 Code 39 — cont. Code 39 Full ASCII In Code 39 decoding, this enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 39 Full ASCII = Disable Code 39 Full ASCII = Enable Product Reference Guide...
  • Page 120: Code 39 Quiet Zones

    Code 39 Quiet Zones = Quiet Zone on one side Code 39 Quiet Zones = Quiet Zones on two sides DEFAULT Code 39 Quiet Zones = Auto Code 39 Quiet Zones = Virtual Quiet Zones on two sides QuickScan® QD2100...
  • Page 121: Code 39 Minimum Reads

    Code 39 Code 39 — cont. Code 39 Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE Code 39 Minimum Reads = 1 DEFAULT Code 39 Minimum Reads = 2 Code 39 Minimum Reads = 3...
  • Page 122: Code 39 Decoding Level

    If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level. This configuration item applies to Code 39 and Code 32. NOTE QuickScan® QD2100...
  • Page 123 Code 39 Code 39 — cont. Code 39 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Code 39 Decoding Level = 1 Code 39 Decoding Level = 2 DEFAULT Code 39 Decoding Level = 3 Code 39 Decoding Level = 4 Code 39 Decoding Level = 5 Product Reference Guide...
  • Page 124: Code 39 Length Control

    For variable length decoding, a minimum and maximum length may be set. Fixed Length — For fixed length decoding, two different lengths may be set. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 39 Length Control = Variable Length Code 39 Length Control = Fixed Length QuickScan® QD2100...
  • Page 125 Code 39 Code 39 — cont. Code 39 Set Length 1 This feature specifies one of the barcode lengths for . Length 1 Code 39 Length Control is the minimum label length if in Mode, or the first fixed length if in Variable Length Mode.
  • Page 126 Select Code 39 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 02 = Length 1 is 2 Characters DEFAULT QuickScan® QD2100...
  • Page 127 Code 39 Code 39 — cont. Code 39 Set Length 2 This feature specifies one of the barcode lengths for . Length 2 Code 39 Length Control is the maximum label length if in Mode, or the second fixed length if Variable Length Mode.
  • Page 128 ENTER/EXIT PROGRAMMING MODE Select Code 39Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT QuickScan® QD2100...
  • Page 129: Code 39 Interdigit Ratio

    Code 39 Code 39 — cont. Code 39 Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 39 labels. ENTER/EXIT PROGRAMMING MODE Code 39 Interdigit Ratio = Disable Code 39 Interdigit Ratio = 1 Code 39 Interdigit Ratio = 2 Code 39 Interdigit Ratio = 3 DEFAULT...
  • Page 130 Code 39 Interdigit Ratio — cont. ENTER/EXIT PROGRAMMING MODE Code 39 Interdigit Ratio = 6 Code 39 Interdigit Ratio = 7 Code 39 Interdigit Ratio = 8 Code 39 Interdigit Ratio = 9 Code 39 Interdigit Ratio = 10 QuickScan® QD2100...
  • Page 131: Code 39 Character Correlation

    Code 39 Code 39 — cont. Code 39 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
  • Page 132: Code 39 Stitching

    ENTER/EXIT PROGRAMMING MODE Code 39 Stitching = Disable DEFAULT Code 39 Stitching = Enable QuickScan® QD2100...
  • Page 133: Code 32 Feature Setting Exceptions

    Code 32 Code 32 The following options apply to the Code 32 (Italian Pharamaceutical Code) symbology. Code 32 Enable/Disable When disabled, the reader will not read Code 32 barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 32 = Disable Code 32 = Enable Code 32 Feature Setting Exceptions The following features are set for Code 32 by using these Code 39 settings: Code 39 Quiet Zones on page 158...
  • Page 134: Code 32 Check Character Transmission

    Code 32 Check Character Transmission = Send Code 32 Start/Stop Character Transmission This option enables/disable transmission of Code 32 start and stop characters. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 32 Start/Stop Character Transmission = Don’t Transmit Code 32 Start/Stop Character Transmission = Transmit QuickScan® QD2100...
  • Page 135: Code 128

    Code 128 Code 128 The following options apply to the Code 128 symbology. Code 128 Enable/Disable When disabled, the reader will not read Code 128 barcodes. ENTER/EXIT PROGRAMMING MODE Code 128 = Disable DEFAULT Code 128 = Enable Expand Code 128 to Code 39 This feature enables/disables expansion of Code 128 labels to Code 39 labels.
  • Page 136: Code 128 Check Character Transmission

    Code 128 Check Character Transmission = Send Code 128 Function Character Transmission Enables/disables transmission of Code128 function characters 1, 2, 3, and 4. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 128 Function Character Transmission = Don’t Send Code 128 Function Character Transmission = Send QuickScan® QD2100...
  • Page 137 Code 128 Code 128 — cont. Code 128 Sub-Code Change Transmission Enables/disables the transmission of “Sub-Code exchange” characters (NOT transmitted by standard decoding). ENTER/EXIT PROGRAMMING MODE DEFAULT Code 128 Sub-Code Change Transmission = Disable Code 128 Sub-Code Change Transmission = Enable Product Reference Guide...
  • Page 138: Code 128 Quiet Zones

    Code 128 Quiet Zones = Quiet Zone on one side Code 128 Quiet Zones = Quiet Zones on two sides DEFAULT Code 128 Quiet Zones = Auto Code 128 Quiet Zones = Virtual Quiet Zones on two sides QuickScan® QD2100...
  • Page 139: Code 128 Minimum Reads

    Code 128 Code 128 — cont. Code 128 Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 128 Minimum Reads = 1 Code 128 Minimum Reads = 2 Code 128 Minimum Reads = 3 Code 128 Minimum Reads = 4...
  • Page 140: Code 128 Decoding Level

    If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level. QuickScan® QD2100...
  • Page 141 Code 128 Code 128 — cont. Code 128 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Code 128 Decoding Level = 1 Code 128 Decoding Level = 2 DEFAULT Code 128 Decoding Level = 3 Code 128 Decoding Level = 4 Code 128 Decoding Level = 5 Product Reference Guide...
  • Page 142: Code 128 Length Control

    For variable length decoding, a minimum and maximum length may be set. Fixed Length — For fixed length decoding, two different lengths may be set. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 128 Length Control = Variable Length Code 128 Length Control = Fixed Length QuickScan® QD2100...
  • Page 143 Code 128 Code 128 — cont. Code 128 Set Length 1 This feature specifies one of the barcode lengths for . Length Code 128 Length Control 1 is the minimum label length if in Mode, or the first fixed length if in Variable Length Mode.
  • Page 144 Select Code 128 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Character DEFAULT QuickScan® QD2100...
  • Page 145 Code 128 Code 128 — cont. Code 128 Set Length 2 This feature specifies one of the barcode lengths for . Length Code 128 Length Control 2 is the maximum label length if in Mode, or the second fixed length if Variable Length Mode.
  • Page 146 Select Code 128 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 80 = Length 2 is 80 Characters DEFAULT QuickScan® QD2100...
  • Page 147: Code 128 Character Correlation

    Code 128 Code 128 — cont. Code 128 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
  • Page 148: Code 128 Stitching

    ENTER/EXIT PROGRAMMING MODE Code 128 Stitching = Disable DEFAULT Code 128 Stitching = Enable QuickScan® QD2100...
  • Page 149: Gs1-128 Enable

    GS1-128 GS1-128 The following options apply to the GS1-128 symbology. (Also known as USS-128, GTIN-128, UCC-128.) GS1-128 Enable This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format. Options are: • Transmit GS1-128 labels in Code 128 data format. •...
  • Page 150: I 2 Of 5 Enable/Disable

    The following options apply to the I 2 of 5 symbology. I 2 of 5 Enable/Disable When disabled, the reader will not read I 2 of 5 barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT I 2 of 5 = Disable I 2 of 5 = Enable QuickScan® QD2100...
  • Page 151: I 2 Of 5 Check Character Calculation

    Interleaved 2 of 5 (I 2 of 5) Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional I 2 of 5 check character. When disabled, any check character in label is treated as a data character.
  • Page 152: I 2 Of 5 Check Character Transmission

    Enable this option to transmit the check character along with I 2 of 5 barcode data. ENTER/EXIT PROGRAMMING MODE I 2 of 5 Check Character Transmission = Don’t Send DEFAULT I 2 of 5 Check Character Transmission = Send QuickScan® QD2100...
  • Page 153 Interleaved 2 of 5 (I 2 of 5) Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read..
  • Page 154: Datalogic 2 Of

    Symbologies Interleaved 2 of 5 (I 2 of 5) — cont. 2 of 5 Decoding Level This configuration item applies to Interleaved 2 of 5, Datalogic 2 of 5 and Standard 2 of 5. NOTE Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
  • Page 155 Interleaved 2 of 5 (I 2 of 5) Interleaved 2 of 5 (I 2 of 5) — cont. 2 of 5 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE 2 of 5 Decoding Level = 1 2 of 5 Decoding Level = 2 DEFAULT 2 of 5 Decoding Level = 3 2 of 5 Decoding Level = 4...
  • Page 156 Fixed Length — For fixed length decoding, two different lengths may be set. ENTER/EXIT PROGRAMMING MODE DEFAULT I 2 of 5 Length Control = Variable Length I 2 of 5 Length Control = Fixed Length QuickScan® QD2100...
  • Page 157: Code

    Interleaved 2 of 5 (I 2 of 5) Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for . Length 1 is I 2 of 5 Length Control the minimum label length if in Mode, or the first fixed length if in Variable Length...
  • Page 158 Symbologies Interleaved 2 of 5 (I 2 of 5) — cont. Datalogic 2 of 5 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select I 2 of 5 Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string.
  • Page 159 Interleaved 2 of 5 (I 2 of 5) Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for . Length 2 is I 2 of 5 Length Control the maximum label length if in Mode, or the second fixed length if in Variable Length...
  • Page 160 Select I 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT QuickScan® QD2100...
  • Page 161: I 2 Of 5 Character Correlation

    Interleaved 2 of 5 (I 2 of 5) Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids.
  • Page 162 ENTER/EXIT PROGRAMMING MODE DEFAULT I 2 of 5 Stitching = Disable I 2 of 5 Stitching = Enable QuickScan® QD2100...
  • Page 163: Datalogic 2 Of 5

    Datalogic 2 of 5 The following options apply to the Datalogic 2 of 5 symbology. Datalogic 2 of 5 Enable/Disable When disabled, the reader will not read Datalogic 2 of 5 barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT Datalogic 2 of 5 = Disable...
  • Page 164 Symbologies Datalogic 2 of 5 — cont. Datalogic 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Datalogic 2 of 5 check character. ENTER/EXIT PROGRAMMING MODE DEFAULT Datalogic 2 of 5 Check Character Calculation = Disable Datalogic 2 of 5 Check Character Calculation = Enable QuickScan®...
  • Page 165: Datalogic 2 Of 5 Minimum Reads

    Datalogic 2 of 5 — cont. Datalogic 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an Datalogic 2 of 5 la- bel must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE...
  • Page 166: Datalogic 2 Of 5 Length Control

    Fixed Length — For fixed length decoding, two different lengths may be set. ENTER/EXIT PROGRAMMING MODE DEFAULT Datalogic 2 of 5 Length Control = Variable Length Datalogic 2 of 5 Length Control = Fixed Length QuickScan® QD2100...
  • Page 167 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See for some examples of how to set this feature. Table 27 Table 27. Datalogic 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES Desired Setting...
  • Page 168 Symbologies Datalogic 2 of 5 — cont. Datalogic 2 of 5 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
  • Page 169 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT Datalogic 2 of 5 LENGTH 2 SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the length setting which was determined in the steps above.
  • Page 170 Symbologies Datalogic 2 of 5 — cont. Datalogic 2 of 5 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
  • Page 171: Datalogic 2 Of 5 Interdigit Maximum Ratio

    This feature specifies the maximum ratio between intercharacter space and module for Datalogic 2 of 5. ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Interdigit Maximum Ratio = Disable Datalogic 2 of 5 Interdigit Maximum Ratio = 1 Datalogic 2 of 5 Interdigit Maximum Ratio = 2...
  • Page 172 Symbologies Datalogic 2 of 5 Interdigit Maximum Ratio — cont. Datalogic 2 of 5 Interdigit Maximum Ratio = 6 Datalogic 2 of 5 Interdigit Maximum Ratio = 7 Datalogic 2 of 5 Interdigit Maximum Ratio = 8 Datalogic 2 of 5 Interdigit Maximum Ratio = 9 Datalogic 2 of 5 Interdigit Maximum Ratio = 10 QuickScan®...
  • Page 173: Datalogic 2 Of 5 Character Correlation

    Datalogic 2 of 5 Datalogic 2 of 5 — cont. Datalogic 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids.
  • Page 174: Datalogic 2 Of 5 Stitching

    Datalogic 2 of 5 — cont. Datalogic 2 of 5 Stitching This option enables/disables stitching for Datalogic 2 of 5 labels. When parts of a Data- logic 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all bar-...
  • Page 175: Codabar Enable/Disable

    Codabar Codabar The following options apply to the Codabar symbology. Codabar Enable/Disable When disabled, the reader will not read Codabar barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT Codabar = Disable Codabar = Enable Product Reference Guide...
  • Page 176: Codabar Check Character Calculation

    Codabar check character. When disabled, any check characters in the label are treated as data characters. ENTER/EXIT PROGRAMMING MODE DEFAULT Codabar Check Character Calculation = Don’t Calculate Codabar Check Character Calculation = Enable AIM standard check char. Codabar Check Character Calculation = Enable Modulo 10 check char. QuickScan® QD2100...
  • Page 177: Codabar Check Character Transmission

    Codabar Codabar — cont. Codabar Check Character Transmission Enable this option to transmit the check character along with Codabar barcode data. ENTER/EXIT PROGRAMMING MODE Codabar Check Character Transmission = Don’t Send DEFAULT Codabar Check Character Transmission = Send Codabar Start/Stop Character Transmission Enable this option to enable/disable transmission of Codabar start and stop characters.
  • Page 178: Codabar Start/Stop Character Set

    This option specifies the format of transmitted Codabar start/stop characters. ENTER/EXIT PROGRAMMING MODE Codabar Check Character Set = ABCD/TN*E Codabar Check Character Set = ABCD/ABCD Codabar Check Character Set = abcd/tn*e DEFAULT Codabar Check Character Set = abcd/abcd QuickScan® QD2100...
  • Page 179: Codabar Start/Stop Character Match

    Codabar Codabar — cont. Codabar Start/Stop Character Match When enabled, this option requires that start and stop characters match. ENTER/EXIT PROGRAMMING MODE DEFAULT Codabar Start/Stop Character Match = Don’t Require Match Codabar Start/Stop Character Match = Require Match Product Reference Guide...
  • Page 180: Codabar Quiet Zones

    ENTER/EXIT PROGRAMMING MODE Codabar Quiet Zones = Quiet Zone on one side Codabar Quiet Zones = Quiet Zones on two sides DEFAULT Codabar Quiet Zones = Auto Codabar Quiet Zones = Virtual Quiet Zones on two sides QuickScan® QD2100...
  • Page 181: Codabar Minimum Reads

    Codabar Codabar — cont. Codabar Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE Codabar Minimum Reads = 1 DEFAULT Codabar Minimum Reads = 2 Codabar Minimum Reads = 3 Codabar Minimum Reads = 4 Product Reference Guide...
  • Page 182: Codabar Decoding Level

    If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level. QuickScan® QD2100...
  • Page 183 Codabar Codabar — cont. Codabar Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Codabar Decoding Level = 1 Codabar Decoding Level = 2 DEFAULT Codabar Decoding Level = 3 Codabar Decoding Level = 4 Codabar Decoding Level = 5 Product Reference Guide...
  • Page 184: Codabar Length Control

    For variable length decoding, a minimum and maximum length may be set. Fixed Length — For fixed length decoding, two different lengths may be set. ENTER/EXIT PROGRAMMING MODE DEFAULT Codabar Length Control = Variable Length Codabar Length Control = Fixed Length QuickScan® QD2100...
  • Page 185: Codabar Set Length 1

    Codabar Codabar — cont. Codabar Set Length 1 This feature specifies one of the barcode lengths for . Length 1 Codabar Length Control is the minimum label length if in Mode, or the first fixed length if in Variable Length Mode.
  • Page 186 ENTER/EXIT PROGRAMMING MODE Select Codabar Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 03 = Length 1 is 3 Characters DEFAULT QuickScan® QD2100...
  • Page 187: Codabar Set Length 2

    Codabar Codabar — cont. Codabar Set Length 2 This feature specifies one of the barcode lengths for . Length 2 Codabar Length Control is the maximum label length if in Mode, or the second fixed length if Variable Length Mode. The length includes the barcode’s start, stop, check and data Fixed Length characters.
  • Page 188 ENTER/EXIT PROGRAMMING MODE Select CodabarLength 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT QuickScan® QD2100...
  • Page 189: Codabar Interdigit Ratio

    Codabar Codabar — cont. Codabar Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Codabar labels. ENTER/EXIT PROGRAMMING MODE Codabar Interdigit Ratio = Disable Codabar Interdigit Ratio = 1 Codabar Interdigit Ratio = 2 Codabar Interdigit Ratio = 3 DEFAULT Codabar Interdigit Ratio = 4 Codabar Interdigit Ratio = 5...
  • Page 190 Symbologies Codabar — cont. Codabar Interdigit Ratio — cont. ENTER/EXIT PROGRAMMING MODE Codabar Interdigit Ratio = 6 Codabar Interdigit Ratio = 7 Codabar Interdigit Ratio = 8 Codabar Interdigit Ratio = 9 Codabar Interdigit Ratio = 10 QuickScan® QD2100...
  • Page 191: Codabar Character Correlation

    Codabar Codabar — cont. Codabar Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
  • Page 192: Codabar Stitching

    ENTER/EXIT PROGRAMMING MODE DEFAULT Codabar Stitching = Disable Codabar Stitching = Enable QuickScan® QD2100...
  • Page 193: Code 11 Enable/Disable

    Code 11 Code 11 The following options apply to the Code 11 symbology. Code 11 Enable/Disable When disabled, the reader will not read Code 11 barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 11 = Disable Code 11 = Enable Product Reference Guide...
  • Page 194: Code 11 Check Character Calculation

    ENTER/EXIT PROGRAMMING MODE Code 11 Check Character Calculation = Disable Code 11 Check Character Calculation = Check C Code 11 Check Character Calculation = Check K DEFAULT Code 11 Check Character Calculation = Check C and K QuickScan® QD2100...
  • Page 195: Code 11 Check Character Transmission

    Code 11 Code 11 — cont. Code 11 Check Character Transmission This feature enables/disables transmission of an optional Code 11 check character. ENTER/EXIT PROGRAMMING MODE Code 11 Check Character Transmission = Don’t Send DEFAULT Code 11 Check Character Transmission = Send Product Reference Guide...
  • Page 196: Code 11 Minimum Reads

    This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE Code 11 Minimum Reads = 1 DEFAULT Code 11 Minimum Reads = 2 Code 11 Minimum Reads = 3 Code 11 Minimum Reads = 4 QuickScan® QD2100...
  • Page 197: Code 11 Length Control

    Code 11 Code 11 — cont. Code 11 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set. Fixed Length —...
  • Page 198 15 Characters 50 Characters zeroes) Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT CODE 11 LENGTH 1 SETTING Scan Two Characters From ‘0’ and ‘2’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’ Appendix E, Keypad Scan ENTER/EXIT PROGRAMMING MODE QuickScan® QD2100...
  • Page 199 Code 11 Code 11 — cont. Code 11 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 11 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 04 = Length 1 is 4 Characters DEFAULT...
  • Page 200 50 Characters zeroes) Length) Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT CODE 11 LENGTH 2 SETTING Scan Two Characters From ‘0’ and ‘0’ ‘0’ and ‘7’ ‘0’ and ‘F’ ‘3’ AND 2’ Appendix E, Keypad Scan ENTER/EXIT PROGRAMMING MODE QuickScan® QD2100...
  • Page 201 Code 11 Code 11 — cont. Code 11 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 11 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT...
  • Page 202: Code 11 Interdigit Ratio

    ENTER/EXIT PROGRAMMING MODE Code 11 Interdigit Ratio = Disable Code 11 Interdigit Ratio = 1 Code 11 Interdigit Ratio = 2 Code11 Interdigit Ratio = 3 DEFAULT Code 11 Interdigit Ratio = 4 Code 11 Interdigit Ratio = 5 QuickScan® QD2100...
  • Page 203 Code 11 Code 11 — cont. Code 11 Interdigit Ratio — cont. ENTER/EXIT PROGRAMMING MODE Code 11 Interdigit Ratio = 6 Code 11 Interdigit Ratio = 7 Code 11 Interdigit Ratio = 8 Code 11 Interdigit Ratio = 9 Code 11 Interdigit Ratio = 10 Product Reference Guide...
  • Page 204: Code 11 Decoding Level

    If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level. QuickScan® QD2100...
  • Page 205 Code 11 Code 11 — cont. Code 11 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Codabar Decoding Level = 1 Codabar Decoding Level = 2 DEFAULT Codabar Decoding Level = 3 Codabar Decoding Level = 4 Codabar Decoding Level = 5 Product Reference Guide...
  • Page 206: Code 11 Character Correlation

    It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 11 Character Correlation = Disable Code 11 Character Correlation = Enable QuickScan® QD2100...
  • Page 207: Code 11 Stitching

    Code 11 Code 11 Stitching This option enables/disables stitching for Code 11 labels. When parts of a Code 11 bar- code are presented to the reader with this feature enabled, the barcode parts will be as- sembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
  • Page 208: Standard 2 Of

    The following options apply to the Standard 2 of 5 symbology. Standard 2 of 5 Enable/Disable When disabled, the reader will not read Standard 2 of 5 barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT Standard 2 of 5 = Disable Standard 2 of 5 = Enable QuickScan® QD2100...
  • Page 209: Standard 2 Of 5 Check Character Calculation

    Standard 2 of 5 Standard 2 of 5 — cont. Standard 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Standard 2 of 5 check character. ENTER/EXIT PROGRAMMING MODE DEFAULT Standard 2 of 5 Check Character Calculation = Disable Standard 2 of 5 Check Character Calculation = Enable Standard 2 of 5 Check Character Transmission This feature enables/disables transmission of an optional Standard 2 of 5 check character.
  • Page 210: Standard 2 Of 5 Minimum Reads

    Standard 2 of 5 Minimum Reads = 3 Standard 2 of 5 Minimum Reads = 4 Standard 2 of 5 Decoding Level 2 of 5 Decoding The Standard 2 of 5 Decoding Level feature is set using Level on page 192 NOTE QuickScan® QD2100...
  • Page 211: Standard 2 Of 5 Length Control

    Standard 2 of 5 Standard 2 of 5 — cont. Standard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set.
  • Page 212 50 Characters Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING Scan Two Characters From ‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’ Appendix E, Keypad Scan ENTER/EXIT PROGRAMMING MODE QuickScan® QD2100...
  • Page 213 Standard 2 of 5 Standard 2 of 5 — cont. Standard 2 of 5 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string.
  • Page 214 Length) Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT STANDARD 2 OF 5 LENGTH 2 SETTING Scan Two Characters From ‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’ Appendix E, Keypad Scan ENTER/EXIT PROGRAMMING MODE QuickScan® QD2100...
  • Page 215 Standard 2 of 5 Standard 2 of 5 — cont. Standard 2 of 5 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string.
  • Page 216: Standard 2 Of 5 Character Correlation

    It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly. ENTER/EXIT PROGRAMMING MODE DEFAULT Standard 2 of 5 Character Correlation = Disable Standard 2 of 5 Character Correlation = Enable QuickScan® QD2100...
  • Page 217: Standard 2 Of 5 Stitching

    Standard 2 of 5 Standard 2 of 5 Stitching This option enables/disables stitching for Standard 2 of 5 labels. When parts of a Stan- dard 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all bar- code proofing requirements are met.
  • Page 218: Isbt

    Enables/Disables ability of imager to decode ISBT 128 labels. ENTER/EXIT PROGRAMMING MODE DEFAULT ISBT 128 = Disable ISBT 128 = Enable ISBT 128 Concatenation Enables/disables ISBT128 concatenation of 2 labels. ENTER/EXIT PROGRAMMING MODE DEFAULT ISBN 128 Concatenation = Disable ISBN 128 Concatenation = Enable QuickScan® QD2100...
  • Page 219: Isbt 128 Force Concatenation

    ISBT 128 ISBT 128 — cont. ISBT 128 Force Concatenation When enabled, this feature forces all ISBT 128 labels to be concatenated. ISBT 128 Concatenation This option is only valid when is enabled. see page 256 NOTE ENTER/EXIT PROGRAMMING MODE DEFAULT ISBT 128 Force Concatenation = Disable ISBT 128 Force Concatenation = Enable...
  • Page 220: Code

    Symbologies Code 4 The following options apply to the Code 4 symbology. Code 4 Enable/Disable Enables/Disables ability of imager to decode Code 4 labels. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 4 = Disable Code 4 = Enable QuickScan® QD2100...
  • Page 221: Code 4 Check Character Transmission

    Code 4 Code 4 — cont. Code 4 Check Character Transmission This feature enables/disables transmission of an optional Code 4 check character. ENTER/EXIT PROGRAMMING MODE Code 4 Check Character Transmission = Don’t Send DEFAULT Code 4 Check Character Transmission = Send Code 4 Hex to Decimal Conversion This feature enables/disables the conversion of hexidecimal label data to decimal label da- ENTER/EXIT PROGRAMMING MODE...
  • Page 222: Code 5 Enable/Disable

    Symbologies Code 5 The following options apply to the Code 5 symbology. Code 5 Enable/Disable Enables/Disables ability of imager to decode Code 5 labels. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 5 = Disable Code 5 = Enable QuickScan® QD2100...
  • Page 223: Code 5 Check Character Transmission

    Code 5 Code 5 — cont. Code 5 Check Character Transmission This feature enables/disables transmission of an optional Code 5 check character. ENTER/EXIT PROGRAMMING MODE Code 5 Check Character Transmission = Don’t Send DEFAULT Code 5 Check Character Transmission = Send Code 5 Hex to Decimal Conversion This feature enables/disables the conversion of hexidecimal label data to decimal label da- ENTER/EXIT PROGRAMMING MODE...
  • Page 224: Code 4 And Code 5 Common Configuration Items

    If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level. This configuration item applies to Code 4 and Code 5. NOTE QuickScan® QD2100...
  • Page 225 Code 4 and Code 5 Common Configuration Items Code 4 and Code 5 Common Configuration Items — cont. Code 4 and 5 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Code 4 and Code 5 Decoding Level = 1 Code 4 and Code 5 Decoding Level = 2 DEFAULT Code 4 and Code 5 Decoding Level = 3 Code 4 and Code 5 Decoding Level = 4...
  • Page 226 ENTER/EXIT PROGRAMMING MODE DEFAULT Code 4 or Code 5 Minimum Reads = 1 Code 4 or Code 5 Minimum Reads = 2 Code 4 or Code 5 Minimum Reads = 3 Code 4 or Code 5 Minimum Reads = 4 QuickScan® QD2100...
  • Page 227: Follett 2 Of

    Follett 2 of 5 Follett 2 of 5 The following options apply to the Follett 2 of 5 symbology. Follett 2 of 5 Enable/Disable Enables/Disables ability of imager to decode Follett 2 of 5 labels. ENTER/EXIT PROGRAMMING MODE DEFAULT Follett 2 of 5 = Disable Follett 2 of 5 = Enable Product Reference Guide...
  • Page 228 Symbologies NOTES QuickScan® QD2100...
  • Page 229: Technical Specifications

    Appendix A Technical Specifications contains Physical and Performance Characteristics, User Environment and Table 35 Regulatory information. provides Standard Cable Pinouts. Table 36 Table 35. Technical Specifications Item Description Physical Characteristics 2.8 in. H x 6.7 in. L x 2.6 in. W Dimensions (7.1 cm H x 17.1 cm L x 6.6 cm W) Weight (without cable)
  • Page 230 5; Code 11; Codabar; GS1-128; Code 93; MSI; GS1 DataBar Omnidi- rectional, GS1 DataBar Limited, GS1 DataBar Expanded; EAN 13 ISBN; Datalogic 2 of 5; Follet 2/5; Code 4, code 5. RS-232 Std., RS-232 Wincor-Nixdorf, RS-232 OPOS, IBM 46xx (ports 5B and 9B), USB Com Std., USB Keyboard, USB Alternate Keyboard, USB...
  • Page 231: Standard Cable Pinouts

    Standard Cable Pinouts Standard Cable Pinouts provide standard pinout information for the imager’s cable. Figure 7 Table 36 Figure 7. Standard Cable Pinouts Bottom of Imager Cable Interface Cable Port Cable Strain Relief Pin 1 Pin 10 To Host Cable Clip (Latch) The signal descriptions in apply to the connector on the imager and are for ref- Table 36...
  • Page 232 NOTES QuickScan® QD2100...
  • Page 233: Standard Defaults

    Appendix B Standard Defaults The most common configuration settings are listed in the “Default” column of Table 37 The settings in this table are as applied to a standard RS-232 interface. See Table 38 a listing of default exceptions to this list as appled to other interface types. Page references are also provided for feature descriptions and programming barcodes for each parameter.
  • Page 234 Country Mode U.S. Keyboard Caps Lock State Caps Lock OFF Numlock Key Numlock Unchanged Send Control Characters Disable Intercode Delay 100 ms Intercharacter Delay No Delay 100 ms USB Keyboard Speed 1 ms USB-OEM USB-OEM Device Usage Handheld Scanner QuickScan® QD2100...
  • Page 235 Parameter Default Your Setting Page Number Data Editing No Global Prefix Global Prefix/Suffix Global Suffix = 0x0D (CR) Global AIM ID Disable Label ID Control Disable Case Conversion Disable Character Conversion No Char Conversion Symbologies UPC-A UPC-A Enable/Disable Enable UPC-A Check Character Transmission Enable Expand UPC-A to EAN-13 Don’t Expand...
  • Page 236: Table Of Contents

    Disable GS1 DataBar Omnidirectional GS1-128 Disable Emulation GS1 DataBar Omnidirectional Minimum Reads GS1 DataBar Expanded GS1 DataBar Expanded Enable/Disable Disable GS1 DataBar Expanded GS1-128 Emula- Disable tion GS1 DataBar Expanded Minimum Reads GS1 DataBar Expanded Length Control Variable QuickScan® QD2100...
  • Page 237 Parameter Default Your Setting Page Number GS1 DataBar Expanded Set Length 1 GS1 DataBar Expanded Set Length 2 GS1 DataBar Limited GS1 DataBar Limited Enable/Disable Disable GS1 DataBar Limited GS1-128 Emulation Disable GS1 DataBar Limited Minimum Reads Code 39 Code 39 Enable/Disable Enable Code 39 Check Character Calculation Calculate...
  • Page 238 Disable I 2 of 5 Stitching Disable Datalogic 2 of 5 Datalogic 2 of 5 Enable/Disable Enable Datalogic 2 of 5 Check Character Calcu- Disable lation Datalogic 2 of 5 Minimum Reads Datalogic 2 of 5 Length Control Variable QuickScan® QD2100...
  • Page 239 Parameter Default Your Setting Page Number Datalogic 2 of 5 Set Length 1 Datalogic 2 of 5 Set Length 2 Datalogic 2 of 5 Character Correlation Disable Datalogic 2 of 5 Stitching Disable Codabar Codabar Enable/Disable Disable Codabar Check Character Calculation Don’t Calculate...
  • Page 240 Code 4 Code 4 Enable/Disable Disable Code 4 Check Character Transmission Enable Code 4 Hex to Decimal Conversion Enable Code 5 Code 5 Enable/Disable Disable Code 5 Check Character Transmission Enable Code 5 Hex to Decimal Conversion Enable QuickScan® QD2100...
  • Page 241 Parameter Default Your Setting Page Number Code 4 and Code 5 Common Configuration Items Code 4 and 5 Decoding Level Code 4 and Code 5 Minimum Reads Follett 2 of 5 Follett 2 of 5 Enable/Disable Disable Product Reference Guide...
  • Page 242: Default Exceptions

    Code Standard 2/5 Label ID Character(s) Codabar Label ID Character(s) Code 128 Label ID Character(s) GS1-128 Label ID Character(s) Datalogic 2 of 5 Label ID Character(s) ISBT 128 Label ID Character(s) UPCE P2 Label ID Character(s) UPCE/P5 Label ID Character(s) UPCE/GS1-128 Label ID Character(s) QuickScan®...
  • Page 243 Default Exceptions Parameter Default Excption EAN8/P2 Label ID Character(s) EAN8/P5 Label ID Character(s) EAN8/GS1-128 Label ID Character(s) EAN13/P2 Label ID Character(s) EAN13/P5 Label ID Character(s) EAN13/GS1-128 Label ID Character(s) GS1 DataBar 14 (Omnidirectional) Label ID Character(s) GS1 DataBar Expanded Label ID Character(s) GS1 DataBar Limited Label ID Character(s) Character Conversion CR to `...
  • Page 244 GS1 DataBar Expanded Label ID Character(s) GS1 DataBar Limited Label ID Character(s) GTIN W/o Add on Label ID Character(s) GTIN Addon 2 Label ID Character(s) GTIN Add on 5 Label ID Character(s) GTIN Add on 8 Label ID Character(s) QuickScan® QD2100...
  • Page 245: Led And Beeper Indications

    Appendix C LED and Beeper Indications The imager’s beeper sounds and its LED illuminates to indicate various functions or er- rors on the imager. An optional “Green Spot” also performs useful functions. The tables below list these indications. One exception to the behaviors listed in the tables is that the imager’s functions are programmable, and may or may not be turned on.
  • Page 246 Label Programming Imager sounds two times at low fre- Mode Cancel Item Cancel label has been scanned. quency and current volume. Entry Except when in sleep mode or when a Good Read LED Duration other than 00 is selected QuickScan® QD2100...
  • Page 247: Error Codes

    Error Codes Error Codes Upon startup, if the imager sounds a long tone, this means the imager has not passed its automatic Selftest and has entered FRU isolation mode. If the imager is reset, the se- quence will be repeated. The following table describes the LED flashes/beep codes asso- ciated with an error found.
  • Page 248 NOTES QuickScan® QD2100...
  • Page 249: Sample Barcodes

    Appendix D Sample Barcodes The sample barcodes in this appendix are typical representations for their symbology types. UPC-A 12345 67890 EAN-13 3 4 5 67 8 9 0 1 2 3 4 0 Code 39 123ABC Code 128 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 Interleaved 2 of 5 12345678901231 Product Reference Guide...
  • Page 250 Sample Barcodes — continued Code 32 Codabar Code 93 Code 11 QuickScan® QD2100...
  • Page 251: Gs1 Databar

    GS1 DataBar (RSS) GS1 DataBar (RSS) GS1 DataBar variants must be enabled to read the barcodes below (see DataBar (RSS) on page 289 NOTE 10293847560192837465019283746029478450366523 (GS1 DataBar Expanded Stacked) 1234890hjio9900mnb (GS1 DataBar Expanded) 08672345650916 (GS1 DataBar Limited) GS1 DataBar-14 55432198673467 (GS1 DataBar Omnidirectional Truncated) 90876523412674 (GS1 DataBar Omnidirectional Stacked)
  • Page 252 NOTES QuickScan® QD2100...
  • Page 253 Appendix E Keypad Use the barcodes in this appendix to enter numbers as you would select digits/characters from a keypad. Product Reference Guide...
  • Page 254 QuickScan® QD2100...
  • Page 255 Product Reference Guide...
  • Page 256 NOTES QuickScan® QD2100...
  • Page 257: Scancode Tables

    Appendix F Scancode Tables Control Character Emulation Control character emulation selects from different scancode tables as listed in this appen- dix. Each of the control character sets below are detailed by interface type in the tables. These apply to Wedge and USB Keyboard platforms. Control Character 00 —...
  • Page 268: Microsoft Windows Codepage 1252

    Microsoft Windows Codepage 1252 Windows-1252 is a character encoding of the Latin alphabet, used by default in the leg- acy components of Microsoft Windows in English and some other Western languages. QuickScan® QD2100...
  • Page 269 Microsoft Windows Codepage 1252 NOTES Product Reference Guide...
  • Page 270 NOTES QuickScan® QD2100...
  • Page 271 Index bar codes Good Read, Beeper RS-232 Pitch baud rate Volume RS-232 parameters Good Read, Beeper – parity Good Read, Beeper Pitch – 256, 258, 260, 263, barcodes Good Read, Beeper Volume – cancel Green Spot numeric barcodes RS-232 parameters parity Beeper Handheld Scanner...
  • Page 272 Request to Send Roll (Tilt) Tolerance RS-232 interface selection RS-232 Serial Connection sample bar codes code 128 code 39 interleaved 2 of 5 select digits/characters Serial Output Skew (Yaw) Tolerance Standard Cable Pinouts Suffix symbology types Table Top Scanner QuickScan® QD2100...
  • Page 273 ASCII Chart ASCII ASCII ASCII ASCII Char. Char. Char. Char. ‘ “ & ’ < >...
  • Page 274 Telephone: 49 (0) 61 51/93 58-0 Telephone: (65) 6435-1311 germany.scanning@datalogic.com singapore.scanning@datalogic.com India Spain and Portugal Datalogic Scanning India Datalogic Scanning Sarl Sucursal en España Telephone: 91- 22 - 64504739 Telephone: 34 91 746 28 60 india.scanning@datalogic.com spain.scanning@datalogic.com Italy United Kingdom...

Table of Contents