4
Remote Control
This series power supply have five standard communication interfaces: RS232,
USB, GPIB, LAN and CAN. The customer can choose any one according to his
demands.
♦ RS232 Interface
♦ USB Interface
♦ GPIB Interface (Only for IT6500(G) Series)
♦ LAN Interface
♦ CAN Communication Port
4.1 RS232 Interface
This series power supply have a DB9 interface on rear panel. Using a cable with
two COM ports to connect power supply and PC. Then please enter the menu
to configure the communication parameters. all SCPI commands can be used
for programming.
RS-232 Data style
RS232 with start bit and stop bit. The start bit and stop bit cannot be edited.
While you could select the odd parity or even parity under the system set. Odd
or EVEN options have been saved in the nonvolatile memory.
Baudrate
Edit baudrate: You can enter the menu setup, select the baudrate among the
following options: 4800/ 9600/ 19200/ 38400/ 57600/ 115200
RS-232 connection
Please use a straight-through RS232 cable with DB9 interface and connect the
RS232 serial port with the controller's serial port(for example. PC). The table as
below gives a detailed description for each pin.
The setup about RS232 in the program should agree with the configuration in
the system set. please enter the system Menu to change the communication
parameters.
Copyright © Itech Electronic Co., Ltd.
Remote Control
83
Need help?
Do you have a question about the IT6500C Series and is the answer not in the manual?
Questions and answers