5. Up time and down time mean the time of establishment from one value to
another value under ON status when the internal standard power dissipater is
enabled.
6. Use 12V/120AH battery for test.
7. When used in parallel, to balance power of each phase, distribute the
instrument to three phases. But must ensure that single machine input voltage
meets Specification requirements.
8. It means the maximum phase current value under minimum work input
voltage.
5.1.18 IT6537C
Parameter
Output Rating ( 0 ℃-40
℃)
Output Resistance
Line regulation
±(%of Output+Offset)
Load regulation
±(%of Output+Offset)
Setup Resolution
Read Back Resolution
Setup Accuracy
(within 12 months,25℃
±5℃)
Output Voltage
Output Current
Internal Sink
Current
1
Output Power
Internal Sink
Power
1
Range
Accuracy
Resolution
Voltage
Current
Voltage
Current
Voltage
Current
Power
Voltage
Current
Power
3
Voltage
Current
Copyright © Itech Electronic Co., Ltd.
IT6537C Ver:V1.4
2
0.25%+375mΩ*A
≤0.01%+100mV
≤0.01%+10mA
≤0.01%+375mV
≤0.05%+20mA
≤0.05%+375mV
Technical Specification
0~1000V
0~20A
0~3A
0~6KW
0~100W
0~166.666Ω
10mΩ
100mV
1mA
0.1W
100mV
1mA
0.1W
≤0.2%+20mA