Sign In
Upload
Manuals
Brands
ITech Manuals
Power Supply
IT6302
ITech IT6302 Output DC Power Manuals
Manuals and User Guides for ITech IT6302 Output DC Power. We have
2
ITech IT6302 Output DC Power manuals available for free PDF download: Programming Manual, User Manual
ITech IT6302 Programming Manual (51 pages)
Triple Output Programmable DC Power Supply
Brand:
ITech
| Category:
Power Supply
| Size: 0 MB
Table of Contents
Limitation of Warranty
3
Warranty
3
Environmental Conditions
4
Regulatory Markings
5
Waste Electrical and Electronic Equiment (WEEE) Directive
5
Compliance Information
6
Table of Contents
7
Chapter1 Remote Control
10
Command Type of SCPI
10
Overview
10
Quality Certification and Assurance
10
Safety Symbols
10
SCPI Command Introduction
10
Safety Precautions
11
Command Format
12
Data Type
14
Communication Interface
15
Chapter2 SCPI Status Register
17
Chapter3 System Commands
18
System:error
18
System:version
18
System:remote
18
System:local
18
System:rwlock[:State]
19
System:beeper
19
Status:questionable[:Event]
19
Status:questionable:enable
20
Status:preset
20
Status:questionable:instrument[:Event]
20
Status:questionable:instrument:enable
21
Status:questionable:instrument:isummary1[:Event]
21
Status:questionable:instrument:isummary1:Enable
21
Status:questionable:instrument:isummary1:Condition
21
Status:questionable:instrument:isummary2[:Event]
22
Status:questionable:instrument:isummary2:Enable
22
Status:questionable:instrument:isummary2:Condition
22
Status:questionable:instrument:isummary3[:Event]
22
Status:questionable:instrument:isummary3:Enable
23
Status:questionable:instrument:isummary3:Condition
23
Status:operation[:Event]
23
Status:operation:enable
24
Status:operation:instrument[:Event]
24
Status:operation:instrument:enable
24
Status:operation:instrument:isummary1[:Event]
25
Status:operation:instrument:isummary1:Enable
25
Status:operation:instrument:isummary1:Condition
25
Status:operation:instrument:isummary2:Enable
26
Status:operation:instrument:isummary2:Condition
26
Status:operation:instrument:isummary3[:Event]
26
Status:operation:instrument:isummary3:Enable
26
Status:operation:instrument:isummary3:Condition
27
Chapter4 Trigger Command
28
Trigger[:Immediate]
28
Trigger:delay
28
Chapter5 Output Commands
29
Output[:State][:All]
29
Output:series[:State]
29
Output:parallel[:State]
29
[Source:]Channel:output[:State]
30
[Source:]Output:protection:clear
30
Chapter6 Current Setting Commands
31
[Source:]Current[:Level][:Immediate][:Amplitude]
31
[Source:]Current[:Level]:Up[:Immediate][:Amplitude]
31
Source:]Current[:Level]:Down[:Immediate][:Amplitude]
32
[Source:]Current[:Level][:Immediate]:Step[:Increment]
32
[Source:]Current[:Level]:Triggered[:Immediate][:Increment]
32
Chapter7 Voltage Setting Commands
34
[Source:]Voltage[:Level][:Immediate][:Amplitude]
34
[Source:]Oltage[:Level]:Up[:Immediate][:Amplitude]
34
[Source:]Voltage[:Level]:Down[:Immediate][:Amplitude]
34
[Source:]Voltage[:Level][:Immediate]:Step[:Increment]
35
[Source:]Voltage:level]:Triggered[:Immediate][:Increment]
35
[Source:]Voltage:limit[:Level]
35
Chapter8 Compound Control Commands
37
[Source:]Apply
37
Chapter9 Measurement Commands
38
Measure[:Scalar]:Current[:DC]
38
Fetch:current[:DC]
38
Measure[:Scalar][:Voltage][:DC]
38
Fetch[:Voltage][:DC]
38
Measure[:Scalar]:Power[:DC]
39
Fetch:power[:DC]
39
Chapter10 Channel Operation Commands
40
Instrument[:Select]
40
Instrument:nselect
40
Instrument:couple[:Trigger]
40
Instrument:combine:series
40
Instrument:combine:parallel
41
Instrument:combine:off
41
Chapter1 Calibration Commands
42
Calibrate:secure[:State]
42
Calibrate:voltage:level
42
Calibrate:voltage[:Data]
42
Calibrate:current:level
43
Calibrate:current[:Data]
43
Calibrate:save
43
Calibrate:initital
43
Calibrate:string
44
Chapter11 IEEE-488 Commands
45
Cls
45
Ese
45
Esr
45
Idn
46
Opc
46
Psc
47
Rst
47
Sre
47
Stb
48
Trg
48
Sav
49
Rcl
49
Tst
49
Advertisement
ITech IT6302 User Manual (28 pages)
Triple Output Programmable
Brand:
ITech
| Category:
Power Supply
| Size: 1 MB
Table of Contents
Table of Contents
2
Security Regulation
3
Safety Symbols
3
Certification and Quality Assurance
3
Introduction
4
Chapter 1 Quick Reference
5
The Front Panel and Rear Panel Description
5
Front Panel
5
The Rear Panel
7
Dimensions
8
Preliminary Checkout
8
Check the List of Supplied Items
8
Power on Pre-Check
8
Checkout Procedure
9
Output Verification
10
If the Power Supply Does Not Turn on
11
How to Exchange the Fuse
11
Adjust the Carrying Handle
12
Chapter 2 Specification
12
Specification
12
Additional Features
14
Chapter 3 Front-Panel Operation
15
Front-Panel Operation Overview
15
Panel Description
16
VFD Description
17
Menu Description
17
Panel Operation
18
Channel Operation
18
Out On/Off
18
Set Voltage
18
Current Operation
19
Save and Recall Operation
19
LVP Operation
20
Key Lock Set
20
Protections
20
Menu Description
20
Communication Module Introduction
26
IT-E121 Communication Module
26
IT-E122 Communication Module
26
Communication between Power Supply and PC
27
Advertisement
Related Products
ITech IT6300 Series
ITech IT6322
ITech IT6322A
ITech IT6333AIT6322B
ITech IT6332B
ITech IT6333B
ITech IT6333A
ITech IT6322B
ITech IT6322C
ITech IT6333C
ITech Categories
Power Supply
Test Equipment
Measuring Instruments
Watch
Racks & Stands
More ITech Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL