through command *SAV,*RCL.Save operation should work in with GROUP.
Each GROUP can save 10sets, and there are 10 GROUP from 0-9.
Saved contents include , and the and power set value of the load. You can also
save the maximum and minimum values of the power supply and load, and
select the load type and number of external loads.
•
•
•
•
•
•
•
•
•
3.8.1 Setting Group Number
To use the save and recall function, firstly, the user need to specify the Group
number in the menu. The procedures are as follows.
1. Press composite keys [Shift]+[P-set](Menu) to enter system menu.
2. Select SYSTEM, press [Enter].
3. Select Memory with Left/Right key and press [Enter] to confirm.
4. Press numeric keys to set the Group value: Group=0.
3.8.2 Save Operation
Save the parameters to nonvolatile memory. The procedures are as follows.
1. Using composite key [Shift]+ [Recall](Save) to save parameter.
voltage set value of source
current set value of source
power set value of source
maximum and minimum values of source
current set value of load
power set of load
maximum and minimum values of load
select the load type
number of external loads
•
Group=0: indicates save (recall) power source parameters in 0-9 sets.
•
Group=1: indicates save (recall) parameters in 10th -19th sets. Under
this condition, number "1" represents to save or recall the 10th
parameters. Number "2" represents to save or recall the eleventh
parameter and so on.
•
Group=2~Group=9 can be understood in the same manner.
Copyright © Itech Electronic Co., Ltd.
Function and Features
22