List Operation - ITech IT6500C Series User Manual

High power and programmable switching power supply
Hide thumbs Also See for IT6500C Series:
Table of Contents

Advertisement

To set loop and CC/CV mode, follow the method below.
1. Press the composite key [Shift]+[P-set](Menu) to enter the Configuring
2. Select CONFIG in the menu and press [Enter] for confirmation.
3. Select Loop-Mode with Right key and press [Enter] for confirmation.
4. Select CV-Loop or CC-Loop to set the loop response speed.
5. Select Priority and set the current priority work mode, which defaults to CV

3.18 LIST Operation

LIST mode comprises 10 files (File1-File10) in total, and each has 10 waves.
Each wave has 10 steps. You need to edit the voltage, current, load current,
Set Priority as CC, CC-Loop as High and CV-Loop as High to represent CC
characteristics entirely. In this way, you can quickly create current and inhibit
current overshoot so as to realize seamless and no-overshoot current
switch.
Waveform characteristics are as shown below. Yellow means output voltage
and green means output current.
When CV mode is selected from CC/CV Priority, the load current
value set in List wave file fails and discharge current is the I-set
value set in the power supply Setup menu. Pay attention to
current value to avoid over-current. For detailed checking and
setting methods, refer to
Menu.
mode.
Copyright © Itech Electronic Co., Ltd.
3.9.8 Load Setup Option
Function and Features
(Load).
42