It6527C - ITech IT6500C Series User Manual

High power and programmable switching power supply
Hide thumbs Also See for IT6500C Series:
Table of Contents

Advertisement

1. Internal absorption current and internal absorption power mean the
absorption current and power of the standard power dissipater inside the power
supply.
2. Resistance programming accuracy differs based on different output current.
For example, 10A Transient 1.0Ω, accuracy: (1.0Ω * 0.25%) +(375mΩ*A /10A)
= 40mΩ.1.0Ω, accuracy: (1.0Ω * 0.25%) +(375mΩ*A /10A) = 40mΩ.
3. Set value accuracy means the set accuracy realized through the panel button
or communication instructions. When external analog is used for programming,
the programming accuracy is 2%FS.
4. Read-back value accuracy means the read-back accuracy realized through
panel display or communication instructions; when external analog is used for
monitoring, the monitoring accuracy is 1%FS.
5. Up time and down time mean the time of establishment from one value to
another value under ON status when the internal standard power dissipater is
enabled.
6. Use 12V/120AH battery for test.
7. When used in parallel, to balance power of each phase, distribute the
instrument to three phases. But must ensure that single machine input voltage
meets Specification requirements.
8. It means the maximum phase current value under minimum work input
voltage.

5.1.17 IT6527C

Parameter
Output Rating ( 0 ℃-40
℃)
Output Resistance
Line regulation
±(%of Output+Offset)
Output Voltage
Output Current
Internal Sink
Current
1
Output Power
Internal Sink
Power
1
Range
Accuracy
2
Resolution
Voltage
Current
Copyright © Itech Electronic Co., Ltd.
Technical Specification
IT6527C Ver:V1.6
0~1000V
0~10A
0~1.5A
0~3000W
0~50W
0~333.333Ω
0.25%+375mΩ*A
10mΩ
≤0.01%+100mV
≤0.01%+5mA
136