3
Function and Features
This chapter describes in detail the use of the front-panel keys and shows how
they are used to accomplish instrument operation. This chapter is divided into
the following sections:
♦ Setting Voltage
♦ Setting Current
♦ Setting Power
♦ Output On/Off Button
♦ Switching Setting Value and Actual Value
♦ Switching Local/Remote Mode
♦ Key Lock Function
♦ Save/Recall Operation
♦ System Menu
♦ Setup Menu
♦ Setting Output Rise Time/Fall Time
♦ Protection Function
♦ Setting Maximum and Minimum Values
♦ Charge Protection
♦ Static Protection Function of Battery
♦ Internal Resistance Setting
♦ CC/CV Priority
♦ LIST Operation
♦ PV Simulation
♦ Built-in Waveform
♦ DC Internal Resistance Measure
♦ Parallel Operation
♦ Analogue Interface (Enhanced Isolation)
3.1 Setting Voltage
The constant voltage range is from 0V to the maximum voltage value. It is very
easy for you to set the constant voltage output. When you press [V-set], this
button will be lit and you can set the constant value. You have 3 solutions to set
the constant voltage value.
•
•
•
Directly input through number keys. Input the value you want to set and then
please press [Enter] or [OK] button to confirm.
Using knob to set value. Press [V-set] button, press [Coarse] button (-
coarse adjustment, change the value in integer bit) or [Fine] button (fine
adjustment, change the value in decimal bit), and then rotate the knob to set
the value.
Using left and right direction key to set value. Press [V-set] button Press
[Coarse] button (coarse adjustment, change the value in integer bit) or
Copyright © Itech Electronic Co., Ltd.
Function and Features
19