Sign In
Upload
Manuals
Brands
ITech Manuals
Power Supply
IT6400 Series
ITech IT6400 Series Bipolar Power Supply Manuals
Manuals and User Guides for ITech IT6400 Series Bipolar Power Supply. We have
4
ITech IT6400 Series Bipolar Power Supply manuals available for free PDF download: Programming Manual, User Manual
ITech IT6400 Series Programming Manual (126 pages)
Bipolar DC Power Supply / Battery Simulator
Brand:
ITech
| Category:
Power Supply
| Size: 0 MB
Table of Contents
Limitation of Warranty
3
Safety Signs
3
Environmental Conditions
4
Safety Precautions
4
Regulation Tag
5
Waste Electrical and Electronic Equipment (WEEE) Directive
5
Compliance Information
6
Table of Contents
7
Chapter1 Remote Control
14
1.1 Overview
14
1.2 SCPI Command Introduction
14
1.3 Command Type of SCPI
14
1.4 Command Format
17
1.5 Data Type
19
1.6 SCPI Register
20
1.7 Remote Operation
22
Chapter2 IEEE-488 Commands
24
CLS - Clear Status
25
ESE <Nrf> - Event Enable
25
Esr
26
Idn
26
Opc
27
Psc
28
Rcl
28
Rst
29
Sav
29
Sre
29
Stb
30
Trg
31
Tst
31
Wai
31
Chapter3 Status Commands
33
Status:questionable
33
Status:questionable:enable
33
Status:questionable:ptransition
34
Status:questionable:ntransition
35
Status:questionable:condition
35
Status:operation
36
Status:operation:enable
36
Status:operation:condition
37
Status:preset
38
Chapter4 System Commands
39
System:posetup
39
System:version
39
System:error
40
System:clear
40
System:local
41
System:remote
41
System:rwlock
42
System:date
42
System:time
43
System:communicate:select
43
System:communicate:protocol
43
System:communicate:gpib:address
44
System:communicate:lan:ip
44
System:communicate:lan:gateway
45
System:communicate:lan:mask
45
System:communicate:lan:socketport
46
System:save
46
Calibrate:initialize
46
Chapter5 Display Commands
48
Display:channel
48
Display:screen
48
Display:brightness
49
Chapter6 Measurement Commands
50
Measure:array:current[N][:DC]
50
Fetch:array:current[N][:DC]
50
Measure:array:voltage[N][:DC]
51
Fetch:array:voltage[N][:DC]
51
Measure:current[N]
51
Fetch:current[N]
51
Measure:current[N]:Acdc
52
Fetch:current[N]:Acdc
52
Measure:current[N]:High
53
Fetch:current[N]:High
53
Measure:current[N]:Low
53
Fetch:current[N]:Low
53
Measure:current[N]:Maximum
54
Fetch:current[N]:Maximum
54
Measure:current[N]:Minimum
55
Fetch:current[N]:Minimum
55
Measure:DVM[N]
55
Fetch:DVM[N]
55
Measure:DVM[N]:Acdc
56
Fetch:DVM[N]:Acdc
56
Measure:voltage[N]
56
Fetch:voltage[N]
56
Measure:voltage[N]:Acdc
57
Fetch:voltage[N]:Acdc
57
Measure:voltage[N]:High
57
Fetch:voltage[N]:High
57
Measure:voltage[N]:Low
58
Fetch:voltage[N]:Low
58
Measure:voltage[N]:Maximum
59
Fetch:voltage[N]: Maximum
59
Measure:voltage[N]:Minimum
60
Fetch:voltage[N]:Minimum
60
Measure[:Scalar]:Power[N][:DC]
60
Fetch[:Scalar]:Power[N][:DC]
60
Sense:current[N]:Detector
61
Sense[N]:Current:mode
62
Sense[N]:Function
62
Sense[N]:Sweep:points
63
Sense[N]:Sweep:tinterval
63
Sense[N]:Sweep:frequency
64
Sense[N]:Window
64
Sense[N]:Window:state
65
Sense[N]:Save
66
Chapter7 Output Command
67
Instrument:couple:output:state
67
Output[N][:State]
67
Output:relay:mode
68
Output:compensation:mode
68
Outp[N]:Type[:Capacitance] <Type
69
Output:dfi
70
Output:dfi:source
70
Output:protection:clear
71
Output[N]:Protection:delay
72
Output:ri:mode
72
Output[N]:Speed
73
Output[N]:Speed:time
74
Output[N]:Voltage[:DC]:Range
74
Output[N]:Delay
75
[Source:]Current[N][:Level][:Immediate][:Amplitude]
75
[Source:]Current:protection:state
76
[Source:]Current[N]:Triggered
76
[Source:]Digital:data
77
[Source:]Digital:function
78
[Source:]Current[N]:Limit:state
78
[Source:]Current[N]:Limit
79
[Source:]Resistance[N][:Level][:Immediate][:Amplitude]
79
[Source:]Resistance:trigger
80
[Source:]Voltage[N][:Level][:Immediate][:Amplitude]
80
[Source:]Voltage[N]:Protection
81
[Source:]Voltage[N]:Protection:state
82
[Source:]Voltage[N]:Trigger
82
[Source:]Voltage[N]:Limit:state
83
[Source:]Voltage[N]:Limit
83
[Source:]Voltage[N]:Maxset
84
[Source:]Voltage[N]:Minset
84
[Source:]Current[N]:Maxset
85
[Source:]Current[N]:Minset
85
Chapter8 Trigger Commands
86
Initiate:sequence
86
Initiate:name
86
Initiate[N]:Continuous:sequence1
87
Initiate[N]:Continuous:name Transient
87
Trigger
87
Trigger[N]:Source
88
Trigger[N]:Sequence2
88
Trigger[N]:Acquire
88
Trigger[N]:Sequence2:Level:current
89
Trigger[N]:Acquire:level:current
89
Trigger[N]:Sequence2:Level:DVM
90
Trigger[N]:Acquire:level:DVM
90
Trigger[N]:Sequence2:Level:voltage
91
Trigger[N]:Acquire:level:voltage
91
Trigger[N]:Sequence2:Slope:current
92
Trigger[N]:Acquire:slope:current
92
Trigger[N]:Sequence2:Slope:DVM
93
Trigger[N]:Acquire:slope:DVM
93
Trigger[N]:Sequence2:Slope:voltage
93
Trigger[N]:Acquire:slope:voltage
93
Trigger[N]:Sequence2:Source
94
Trigger[N]:Acquire:source
94
Trigger[N]:Sequence2:Mode
95
Trigger[N]:Acquire:mode
95
Chapter9 Trace Commands
96
Trace[N]:Clear
96
Trace[N]:Data
96
Trace[N]:Points:actual
96
Trace[N]:Point
97
Trace:feed
97
Trace[N]:Feed:control
98
Trace[N]:Statistics
98
Trace[N]:Clear
99
Trace[N]:Save
99
Chapter10 Scope Commands
101
Scope:voltage:range
101
Scope:current:range
101
Scope:time:base
102
Scope:runstop <Bool
102
Scope:auto
103
Scope[N]:Show
103
Scope[N]:Voltage:base
103
Scope[N]:Current:base
104
Scope[N]:DVM:base
104
Scope[N]:Voltage:triger
105
Scope[N]:Current:triger
105
Scope[N]:DVM:triger
106
Scope[N]:Triger:source
106
Scope[N]:Triger:mode
107
Scope[N]:Triger:slope
108
Scope:triger:delay
108
Scope[N]:Data
109
Chapter11 Battery Commands
110
Battery[N]:Group <Nrf
110
Battery[N]:Point <Nrf
110
Battery[N]:Total <Nrf
111
Battery[N]:Paramneter <Nrf><Nrf><Nrf
111
Battery[N]:Voltage:shut <Nrf
112
Battery[N]:Voltage:shut:state <BOOL
112
Battery[N]:Capacity:shut <Nrf
113
Battery[N]:Capacity:shut:state <BOOL
113
Battery[N]:Current:shut <Nrf
114
Battery[N]:Current:shut:state <BOOL
114
Battery[N]:Time:shut <Nrf
115
Battery[N]:Time:shut:state <BOOL
115
Battery[N]:Start
116
Battery[N]:Stop
116
Battery[N]:Capacity:clear
117
Battery[N]:Save
117
Battery[N]:Clear
117
Battery[N]:Recall:select <NR1
118
Battery[N]:Mode
118
Battery[N]:Voltage <Nrf
118
Battery[N]:Current <Nrf
119
Chapter12 List Commands
120
List[N]:Group <Nrf
120
List[N]:Period <Nrf
120
List[N]:Total <Nrf
121
List[N]:Point <Nrf
121
List[N]:Paramneter <Nrf>,<Nrf>,<Nrf>,<Nrf
122
List[N]:Group:select <Nrf
122
List[N]:Group:clear:select
123
List[N] <BOOL
123
List[N]:Run:state
123
List:triger
124
List[N]:Step
124
List[N]:Save
124
Advertisement
ITech IT6400 Series Programming Manual (128 pages)
Bipolar DC Power Supply / Battery Simulator
Brand:
ITech
| Category:
Test Equipment
| Size: 0 MB
Table of Contents
Limitation of Warranty
3
Safety Signs
3
Environmental Conditions
4
Safety Precautions
4
Regulation Tag
5
Waste Electrical and Electronic Equipment (WEEE) Directive
5
Compliance Information
6
Table of Contents
7
Chapter1 Remote Control
13
1.1 Overview
13
1.2 SCPI Command Introduction
13
1.3 Command Type of SCPI
13
1.4 Command Format
16
1.5 Data Type
18
1.6 SCPI Register
19
1.7 Remote Operation
21
Chapter2 IEEE-488 Commands
23
CLS - Clear Status
24
ESE <Nrf> - Event Enable
24
Esr
25
Idn
25
Opc
26
Psc
27
Rcl
27
Rst
28
Sav
28
Sre
28
Stb
29
Trg
30
Tst
30
Wai
31
Chapter3 Status Commands
32
Status:questionable
32
Status:questionable:enable
32
Status:questionable:ptransition
33
Status:questionable:ntransition
34
Status:questionable:condition
34
Status:operation
35
Status:operation:enable
35
Status:operation:condition
36
Status:preset
37
Chapter4 System Commands
38
System:posetup
38
System:version
38
System:error
39
System:clear
39
System:local
40
System:remote
40
System:rwlock
41
System:date
41
System:time
42
System:communicate:select
42
System:communicate:protocol
42
System:communicate:gpib:address
43
System:communicate:lan:ip
43
System:communicate:lan:gateway
44
System:communicate:lan:mask
44
System:communicate:lan:socketport
45
System:save
45
Calibrate:initialize
45
Chapter5 Display Commands
47
Display:screen
47
Display:brightness
47
Chapter6 Measurement Commands
49
Measure:array:current
49
Fetch:array:current
49
Measure:array:voltage
50
Fetch:array:voltage
50
Measure:current
50
Fetch:current
50
Measure:current:acdc
51
Fetch:current:acdc
51
Measure:current:high
52
Fetch:current:high
52
Measure:current:low
52
Fetch:current:low
52
Measure:current:maximum
53
Fetch:current:maximum
53
Measure:current:minimum
54
Fetch:current:minimum
54
Measure:DVM
54
Fetch:DVM
54
Measure:DVM:acdc
55
Fetch:DVM:acdc
55
Measure:voltage
55
Fetch:voltage
55
Measure:voltage:acdc
56
Fetch:voltage:acdc
56
Measure:voltage:high
56
Fetch:voltage:high
56
Measure:voltage:low
57
Fetch:voltage:low
57
Measure:voltage:maximum
58
Fetch:voltage:maximum
58
Measure:voltage:minimum
58
Fetch:voltage:minimum
58
Measure[:Scalar]:Power[:DC]
59
Fetch[:Scalar]:Power[:DC]
59
Sense:current:detector
60
Sense:current:mode
60
Sense:function
61
Sense:sweep:points
61
Sense:sweep:tinterval
62
Sense:sweep:frequency
63
Sense:window
63
Sense:window:state
64
Sense:save
64
Chapter7 Output Command
66
Output[:State]
66
Output:off:mode
66
Output:compensation:mode
67
Outp:type[:Capacitance] <Type
68
Output:dfi
68
Output:dfi:source
69
Output:protection:clear
70
Output:protection:delay
70
Output:ri:mode
71
Output:speed
72
Output:speed:time
72
Output:voltage[:DC]:Range
73
Output:delay
73
[Source:]Current[:Level][:Immediate][:Amplitude]
74
[Source:]Current:protection:state
75
[Source:]Current:triggered
75
[Source:]Digital:data
76
[Source:]Digital:function
77
[Source:]Current:limit:state
77
[Source:]Current:limit
78
[Source:]Resistance[:Level][:Immediate][:Amplitude]
79
[Source:]Resistance:trigger
79
[Source:]Voltage[:Level][:Immediate][:Amplitude]
80
[Source:]Voltage:protection
80
[Source:]Voltage:protection:state
81
[Source:]Voltage:trigger
82
[Source:]Voltage:limit:state
83
[Source:]Voltage:limit
83
[Source:]Voltage:maxset
84
[Source:]Voltage:minset
84
[Source:]Current:maxset
84
[Source:]Current:minset
85
Chapter8 Trigger Commands
86
Abort
86
Initiate:sequence
86
Initiate:name
86
Initiate:continuous:sequence1
87
Trigger
87
Trigger:source
88
Trigger:sequence2
89
Trigger:acquire
89
Trigger:sequence2:Level:current
89
Trigger:acquire:level:current
89
Trigger:sequence2:Level:DVM
90
Trigger:acquire:level:DVM
90
Trigger:sequence2:Level:voltage
91
Trigger:acquire:level:voltage
91
Trigger:sequence2:Slope:current
92
Trigger:acquire:slope:current
92
Trigger:sequence2:Slope:DVM
93
Trigger:acquire:slope:DVM
93
Trigger:sequence2:Slope:voltage
94
Trigger:acquire:slope:voltage
94
Trigger:sequence2:Source
95
Trigger:acquire:source
95
Trigger:sequence:mode
95
Trigger:acquire:mode
95
Chapter9 Trace Commands
97
Trace:clear
97
Trace:data
97
Trace:points:actual
97
Trace:point
98
Trace:feed
98
Trace:feed:control
99
Trace:statistics
99
Trace:autoclear
100
Trace:save
100
Chapter10 Scope Commands
102
Scope:voltage:range
102
Scope:current:range
102
Scope:time:base
103
Scope:runstop <Bool
104
Scope:auto
104
Scope:show
104
Scope:voltage:base
105
Scope:current:base
106
Scope:DVM:base
106
Scope:voltage:triger
107
Scope:current:triger
108
Scope:DVM:triger
109
Scope:triger:source
109
Scope:triger:mode
110
Scope:triger:slope
110
Scope:triger:delay
111
Scope:data
111
Chapter11 Battery Commands
113
Battery:group <Nrf
113
Battery:point <Nrf
113
Battery:total <Nrf
114
Battery:paramneter <Nrf><Nrf><Nrf
114
Battery:voltage:shut <Nrf
114
Battery:capacity:shut <Nrf
115
Battery:current:shut <Nrf
116
Battery:time:shut <Nrf
117
Battery:start
117
Battery:stop
117
Battery:capacity:clear
118
Battery:save
118
Battery:clear
118
Battery:recall:select <NR1
119
Battery:mode
119
Battery:voltage <Nrf
119
Battery:current <Nrf
120
Chapter12 List Commands
122
List:group <Nrf
122
List:period <Nrf
122
List:total <Nrf
123
List:point <Nrf
123
List:paramneter <Nrf>,<Nrf>,<Nrf>,<Nrf
124
List:group:select <Nrf
124
List:group:clear:select
125
List <Bool
125
List:run:state
125
List:triger
126
List:step
126
List:save
126
List:triger:enable
126
List:triger:disable
127
ITech IT6400 Series User Manual (104 pages)
Bipolar DC Power Supply/Battery Simulator
Brand:
ITech
| Category:
Power Supply
| Size: 2 MB
Table of Contents
Limitation of Warranty
3
Safety Signs
3
Environmental Conditions
4
Safety Precautions
4
Regulation Tag
5
Waste Electrical and Electronic Equipment (WEEE) Directive
5
Compliance Information
6
Table of Contents
7
Chapter1 Quick Reference
9
Brief Introduction
9
Introduction of Front Panel
10
Introduction of Keyboard
11
Introduction of Interface Display Information
12
Introduction of Rear Panel
14
Menu at a Glance
15
Chapter2 Inspection And Installation
21
Verifying the Shipment
21
Instrument Size Introduction
21
Rack Mounting
24
Connecting the Power Cord
24
DUT Connection
25
Power-On Self-Test
28
Chapter3 Basic Operation
31
Local/Remote Operation Mode Switching
31
Output On/Off Control
31
Key Lock Function
31
Screen Capture Function
31
Save/Recall Operation
32
Triggering Function
34
Protection Function
35
Digital Quantity Control Interface
38
Series Operation
42
Chapter4 Power Supply Function
43
Basic Concepts
43
Setting of Measurement Function and Interface Display
46
Setting of Output Parameters
48
Setting of Filter
49
Chapter5 Waveform Display Function
51
Basic Concepts
51
Setting of Knob Functions
54
Horizontal Control and Vertical Control
56
Setting of Trigger Configuration
57
Chapter6 Battery Simulation Function
59
Basic Concepts
59
Battery Charging Function
63
Battery Discharging Function
64
Battery Characteristic Simulation
66
Chapter7 List Function
73
Basic Concepts
73
List Operation
75
Chapter8 Routine Maintenance
80
Error Information References
80
Daily Maintenance
80
Contact of ITECH Engineers
81
Returning Your Power for Service
82
Chapter9 Technical Specification
83
Chapter10 Remote Operation Mode
102
USB Interface
102
GPIB Interface
102
LAN Interface
102
Appendix
103
Specifications of Red and Black Test Lines
103
Advertisement
ITech IT6400 Series User Manual (84 pages)
High-speed and High-precision Linear Power Supply
Brand:
ITech
| Category:
Power Supply
| Size: 1 MB
Table of Contents
Limitation of Warranty
3
Safety Signs
3
Environmental Conditions
4
Safety Precautions
4
Regulation Tag
5
Waste Electrical and Electronic Equipment (WEEE) Directive
5
Compliance Information
6
Table of Contents
7
Chapter1 Inspection And Installation
9
Verifying the Shipment
9
Instrument Size Introduction
10
Rack Mounting
11
Connecting the Power Cord
11
DUT Connection
12
Chapter2 Quick Start
16
Brief Introduction
16
Introduction of Front Panel
17
Introduction of Keyboard
17
Introduction of Interface Display Information
18
Introduction of Interface Symbols
19
Introduction of Rear Panel
20
Power-On Self-Test
21
Chapter3 Basic Operation
24
Local/Remote Operation Mode Switching
24
Output On/Off Control
24
System Menu Function (System)
24
Config Menu Function (Config)
25
Math Menu Function (Math)
27
Key Lock Function
28
Screen Capture Function
28
Save/Recall Operation
28
Triggering Function
29
Protection Function
30
Digital Quantity Control Interface
33
Series Operation
35
Chapter4 Power Supply Function
37
Basic Concepts
37
Setting of Measurement Function and Interface Display
40
Setting of Output Parameters
40
Setting of Filter
41
Chapter5 Waveform Display Function
43
Basic Concepts
43
Setting of Knob Functions
45
Horizontal Control and Vertical Control
47
Setting of Trigger Configuration
48
Chapter6 Battery Simulation Function
50
Basic Concepts
50
Battery Charging Function
53
Battery Discharging Function
53
Battery Characteristic Simulation
54
Chapter7 List Function
61
Basic Concepts
61
List Operation
63
Chapter8 Routine Maintenance
68
Error Information References
68
Daily Maintenance
68
Contact of ITECH Engineers
69
Returning Your Power for Service
70
Chapter9 Technical Specification
71
Chapter10 Remote Operation Mode
82
USB Interface
82
GPIB Interface
82
LAN Interface
82
Appendix
83
Specifications of Red and Black Test Lines
83
Advertisement
Related Products
ITech IT6412
ITech IT6411
ITech IT6431
ITech IT6432
ITech IT6433
ITech IT6411S
ITech IT6402
ITech IT6412S
ITech IT6432S
iTech IT6524D
ITech Categories
Power Supply
Test Equipment
Measuring Instruments
Watch
Racks & Stands
More ITech Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL