Oce Eco Solvent CS9350 Manual page 186

Hide thumbs Also See for Eco Solvent CS9350:
Table of Contents

Advertisement

Display
12
[****] Check Ink
13
[****] S/C ReadErr
14
[****] S/C Col.Err
15
[*] S/C Ink Err
16
[*] S/C CodeErr
17
[*] Broken Chip
18
Full WasteInkTank
19
Life Times
[Head]
20
Life Times
[Pump]
21
Life Times
[CR Motor]
22
Life Times
[PF Motor]
23
[****] Change plug
24
No connector cap
25
Color measuring mode error
(Take Up Roll)
26
Color measuring mode error
(Media detection)
27
Color measuring mode error
(Media width)
Description
Printer cannot identify the ink
cartridge or ink pack
correctly.
Reading Smart chip has been
failed.
Ink cartridges are inserted in
wrong slots.
The ink cannot be used for
this printer.
Inserted Ink cartridge is not a
proper one.
Smart Chip has been broken. Insert new Ink cartridges.
The waste fluid tank is full.
(Stops operation)
The operational life of the
print head has almost expired.
(Continues operation)
The operational life of the
pump motor has almost
expired.
(Continues operation)
The life CR motor is almost
expired.
(Continues operation)
The operational life of the PF
motor has almost expired.
(Continues operation)
Time for replacing Connector
rubber of High-capacity pack
adapter (option).
Connector cap is removed
from the connector.
Media ejection mode is set to
"Take-up".
Media detection menu is set to
"Off".
The width of the media
installed does not match the
color target to be measured.
7-186
CS9350 User's Guide
Remedy
•Insert the ink cartridge or ink
pack again.
Insert Ink cartridges again. If
Smart chip still cannot be
read, insert new Ink
cartridges.
Insert ink cartridges correctly
again.
Contact your local Océ
representative.
Contact your local Océ
representative.
Dispose of waste fluid.
Contact your local Océ
representative.
Contact your local Océ
representative.
Contact your local Océ
representative.
Contact your local Océ
representative.
Replace Connector rubber.
Install Connector cap to the
connector of
Spectrophotometer on Print
head.
Change the setting to "Off".
Change the setting to either
"Width" or "Top & Width".
Remove the media currently
set, and set a correct color
target.
Reference
6.1.1 Replacing
ink cartridges
6.1.1 Replacing
ink cartridges
6.1.1 Replacing
ink cartridges
6.1.1 Replacing
ink cartridges
6.1.1 Replacing
ink cartridges
6.3 Disposal of
waste fluids
"3.2 Replacing
connector rubber" of
High-capacity pack
adapter manual.
4.5 Using
spectrophotometer
5.1.6 Output
Mode menu
5.1.4 Media
Initial menu
3.4 Loading