6.5.2 GPIO Plus PWC shutter

Example: 10µs unit pulse width exposure control (PWC).
Pixel clock is 60MHz. 600 clocks (700-100) equal 10µs.
Feature
c)Acquisition
and
Trigger controls
JAI Acquisition and
Trigger Control
Pulse Generators
Fig.13.
Pulse Generator Timing Example 1
BM-500GE / BB-500GE
Trigger selector
Trigger Mode
JAI
Exposure
Mode
Pulse Generator
Pulse Generator 0 Selector
selector
Clock Choice
Counter Dividing Value
Length Counter 0
Start point Counter 0
Repeat Count 0
End point Counter 0
Counter Clear 0
Trigger source
20
Value
ON
Pulse width control
Line 5 =OPT IN 1
1 = Pixel Clock (30MHz)
0 = Pass through
1000 Clocks
100 Clocks
1
700 Clocks
Rising Edge
pulse generator 0