Data and marking

2.8
The machine's general technical data is provided in the follow-
ing table:
TECHNICAL DATA
220-240 V
3.650-4.650 W
380-415 V
Frequency
50-60 Hz
Heating unit
Dimensions (LxWxH)
745x575x605 mm
Safety valve calibra-
0,19 MPa (1,9 bar) +/- 0,015 MPa
tion
Heating unit operat-
ing pressure
Mains water pressure
0,15 - 0,6 MPa MAX (1,5 - 6 bar MAX)
Coffee dispensing
pressure
Working environment
temperature
Sound pressure level
In compliance with directive 2006/42/CE, the machine is
marked with the CE code with which the manufacturer de-
clares under his responsibility that the machine is safe for per-
sons and things.
Alternative markings can be affixed according to the target
markets, provided they comply with current product regula-
tions.
The nameplate which provides the appropriate markings,
identification data and specific technical data, is affixed under
the drain tray.
An example of a nameplate is provided below.
MARCHIO COMMERCIALE
WEGA MACCHINE PER CAFFÈ S.r.l.
Via C. Bardini,1 SUSEGANA (TV) - ITALY
Tel. +39.0438.1799700 Fax +39.0438.1884890
S/N:
V
When contacting the Manufacturer, always provide the follow-
ing information:
• S/N - machine serial number.
• Mod. - machine model.
• Y - year of manufacture.
USER manual
2GR
3GR
5.150 W
50-60 Hz
9,5 l
15,5 l
985x575x605 mm
0,08 - 0,14 MPa (0,8 - 1,4 bar)
0,8 - 0,9 MPa (8 - 9 bar)
5 - 35°C
95° U.R.MAX
< 70 dB
Mod.
Y
Hz
W
MADE IN ITALY
The appliance data can also be found on the label located on
the machine's packaging.
The nameplate is affixed under the drain tray
It is forbidden to remove or modify the nameplate.
Should it deteriorate or become illegible, contact the
Technician or Manufacturer.

3. STORAGE

The machine is stored by the Manufacturer or Technician.

4. INSTALLATION

The machine must only be installed by the Technician.
When the machine is being installed, the Technician
must replace the water in the hydraulic circuits.
The machine's support base must be perfectly flat, not
incline by more than 2° and have no irregularities.
The electrical system must be equipped with a suit-
able residual-current device in compliance with cur-
rent laws and safety regulations.

5. COMMISSIONING

The machine must only be commissioned by the Technician.

6. OPERATION

Safety precautions

6.1
Carefully read the instructions provided in chapter "I.
SAFETY PRECAUTIONS" on page 25.

Emissions

6.2
Vibrations
Under conditions of use that comply with the instructions for
correct use provided in this manual, any detected vibrations do
not give rise to dangerous situations.
WBAR