MTU Detroit Diesel 183 Series Technical Publication page 320

Table of Contents

Advertisement

Group
07
Subgroup
8234
Page
4
20080/1 E 99-06
Engines without electronic diesel control:
Remove fuel supply line to injection pump.
Connect H.P. pump, supply line (8)
part No. 422 589 00 71 00.
Remove return line and overflow valve on injection
pump.
Seal injection pump return with plug (5) from adapters,
part No. 403 589 00 91 00.
Set injection pump lever to full load and lock.
Remove injection line to 1st engine cylinder . Connect
test line with sight glass (4) from H.P. pump, part No.
422 589 00 71 00, to injection pump connection for 1st
engine cylinder .
Special wrench
Special wrench
H.P. pump
Adapters
Install rotating device and set engine approx. ½ rotation
before TDC.
Rotating device
Connect H.P. pump part No. 422 589 00 71 00 to a 12-
Volt battery and switch on.
Note
A charge-pressure-dependent full-load stop "LDA" is
installed in engines with Bosch governors. For this
reason, when checking start of injection the charge air
line must be disconnected from governor and line of
hand pump, part No. 124 589 15 21 00 must be
installed. The governor is subjected to pressure of 2 bar
Task Description
000 589 07 03 00
000 589 50 03 00
422 589 00 71 00
403 589 00 91 00
407 589 00 63 00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents