Task Description
20080/1 E 98-12
Position dial gauge feeler (arrow) on partition on
cylinder crankcase and read off balcony depth.
B Turning device without measuring point
Remove the machine approx. 0.3 mm before reaching
the determined balcony depth and measure the balcony
depth again with the dial gauge to ensure that the
desired final dimension has also been reached. The
machine must be centred after every measurement.
Dial gauge
001 589 53 21 00
Dial gauge holder
Lift up the fast adjusting ring (2) and push the turning
chisel (1) back into its initial position. Adjust to 0.05 mm
with advance nut and repeat turning procedure until
desired dimension has been reached.
Switch off magnet and lift off machine.