9.1.41 LPCOverVoltageError (i)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
9.1.42 LPCHighTemperatureError (j)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
9.1.43 LPCSelftestError (k)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
2022-11
LPCOverVoltageError
Connector
The charging point controller has detected an overvoltage.
Connector
•
New charging processes cannot be started
•
The error is shown on the display
i
Check the mains supply.
LPCHighTemperatureError
Connector
The charging point controller has detected a temperature that is too high.
Connector
•
New charging processes cannot be started
•
The error is shown on the display
j
Check the location of the charging system for direct sunlight or external
heating. Allow the charging system to cool down. Notify customer service if
the error persists.
LPCSelftestError
Connector
The self-test of the charging point controller has failed.
Connector
•
New charging processes cannot be started
•
The error is shown on the display
k
Switch the complete charging system off and on again. Notify customer
service if the error persists.
A01Axxxxxx.xx | 04