9.1.32 samInternalError (9)

Name
Area
Description
Reported by:
Handling
Indication on display
Action

9.1.33 UnlockPlugFailure (a)

Name
Area
Description
Reported by:
Handling
Indication on display
Action

9.1.34 OutletCloseError (b)

Name
Area
Description
Reported by:
Handling
Indication on display
Action
88
samInternalError
Connector
The SAM reports an internal error.
SAMAdapter
The charging process is aborted
The error is shown on the display
No new charging process possible
9
No action possible by operator. Notify customer service.
UnlockPlugFailure
Connector
The plug could not be unlocked.
Connector
New charging processes cannot be started
The error is shown on the display
a
Eliminate possible tensile stress on the charging cable. Notify customer
service if the error persists.
OutletCloseError
Connector
The socket could not be closed (error when closing or locking the sliding
cover).
Connector
New charging processes cannot be started
The error is shown on the display
b
Check the socket for foreign objects. Notify customer service if the error
persists.