9.1.35 LPCCommunicationError (c)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
9.1.36 CableError (d)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
9.1.37 RCSensorTestError (e)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
2022-11
LPCCommunicationError
Connector
Internal error.
Connector
•
New charging processes cannot be started
•
The error is shown on the display
c
Switch the complete charging system off and on again. Notify customer
service if the error persists.
CableError
Connector
An unauthorised charging cable has been detected (13 A cable or undefined
cable).
Connector
•
Charging cannot be started with this cable
•
The error is shown on the display
d
Only use approved charging cables.
RCSensorTestError
Connector
The test of the 6mA sensor was not successful.
Connector
•
New charging processes cannot be started
•
The error is shown on the display
e
No action possible by operator. Notify customer service.
A01Axxxxxx.xx | 04
89