9.1.17 TemperatureSensorLowLimitViolation (S)

Name
Area
Description
Reported by:
Handling
Indication on display
Action

9.1.18 AutomaticRcdTestRunning (T)

Name
Area
Description
Reported by:
Handling
Indication on display
Action

9.1.19 AutomaticRcdTestFailed (U)

Name
Area
Description
Reported by:
Handling
Indication on display
Action
2022-11
TemperatureSensorLowLimitViolation
Connector
The error occurs when the temperature sensor delivers values below its valid
range.
Connector
The error is shown on the display
The maximum charging current is lowered
S
Check the temperature at the location of the charging system. Notify
customer service if the error persists.
AutomaticRcdTestRunning
Station
An automatic RCD switch test is carried out.
Station
The message is shown on the display
T
No action necessary.
AutomaticRcdTestFailed
Connector
The automatic test of the RCD was successful.
Connector
The charging point is out of service
The error is shown on the display
U
No action possible by operator. Notify customer service.
A01Axxxxxx.xx | 04