9.1.20 RCSensorTestRunning (W)

Name
Area
Description
Reported by:
Handling
Indication on display
Action

9.1.21 DcPsuConnectionFailure (X)

Name
Area
Description
Reported by:
Handling
Indication on display
Action

9.1.22 DclnsulationCodeWarning (Y)

Name
Area
Description
Reported by:
Handling
Indication on display
Action
84
RCSensorTestRunning
Connector (AC)
An automatic test of the 6mA sensor is carried out.
Connector
The message is shown on the display
W
No action necessary.
DcPsuConnectionFailure
Station (DC)
If the error occurs, there is a communication problem between the CCU
board in the control unit and the PSU board in the power unit.
Station
The error is shown on the display
- Ongoing DC charging processes are terminated
X
Switch the complete charging system off and on again. Notify customer
service if the error persists.
DclnsulationCodeWarning
Connector (DC)
An insulation warning has occurred during a DC charging process.
Connector
The error is shown on the display
Y
Switch the complete charging system off and on again. Notify customer
service if the error persists.