5.10.10 Connecting the Ethernet cable

ATTENTION
When connecting the LSA terminals, the minimum cross-section of the individual strands of the network
cable must not be less than AWG 26. When using a smaller cross-section than AWG 26, it cannot be
guaranteed that a connection can be established.
NOTE
As a network cable to be used on the network side, we recommend using a cable with the following
designation and article number:
Designation: HELUKAT 600E S/FTP PVC
Article number: 802167, S/FTP 4x2xAWG23/1 PVC (S-STP)
1
Fig. 24: Ethernet connection
3.
Strip the insulation from the data connection cable above the shield clamp.
4.
Place the wire pairs of the data connection cable on the other side of the cable and the colour
coding on the LSA insulation cutting clamp (1) with the attachment tool in accordance with the
layout diagram.
46
Connection via RJ45 socket:
1.
Guide the prefabricated network cable or data
connection cable through the line channel provided
and fix it in place with the cable ties supplied.
2.
Crimp the RJ45 plug onto the data line or use a
2
prefabricated network cable and connect it to the RJ
socket (2).
Connection via LSA terminal:
1.
Route the data connection line through the intended
3
line channel and fix it with the cable ties supplied.
2.
Remove the insulation sheath of the data connection
line to just below the shield clamp (3) down to the
braided shield and press the line into the terminal.
Make sure that the shield makes good contact with the
terminal.