9.1.2
GroundFailure (B)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
9.1.3
HighTemperature (C)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
9.1.4
InternalError (D)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
78
GroundFailure
Connector (AC/ DC)
OCPP1.6: Ground fault circuit interrupter has been activated. The RCD switch,
the circuit breaker or the 6mA sensor of the connector has tripped,
protective function.
Station
•
The error is shown on the display
B
Have a qualified electrician check the RCD switch on site. Switch the FI switch
on again. Notify customer service if the error persists.
HighTemperature
Station
OCPP1.6: Temperature inside Charge Point is too high. Temperature inside
Charge Point is too high.
Station
•
The error is shown on the display
C
No action possible by operator. Notify customer service.
InternalError
Station
OCPP1.6: Error in internal hardware or software component. For example,
errors during initialisation of the socket module.
Connector
•
The connector terminates the charging process
•
The error is shown on the display
D
No action possible by operator. Notify customer service.