9.1.26 DclnsulationTestFailureOnCharge (3)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
9.1.27 samTransactionMemoryFull (4)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
9.1.28 samEVSEIDMemoryFull (5)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
86
DclnsulationTestFailureOnCharge
Connector (DC)
The insulation test during the charging process has found an error.
Connector
•
The charging process is aborted
•
The error is shown on the display
3
Switch the complete charging system off and on again. Notify customer
service if the error persists.
samTransactionMemoryFull
Connector
The error occurs when the SAM has no more free memory for new charging
processes.
SAMConnector
•
The charging process is aborted
•
The error is shown on the display
•
No new charging process possible
4
No action possible by operator. Notify customer service.
samEVSEIDMemoryFull
Connector
The error occurs when the SAM has no more free memory for new
configuration parameters.
Connector
•
The charging process is aborted
•
The error is shown on the display
•
No new charging process possible
5
No action possible by operator. Notify customer service.
A01Axxxxxx.xx | 04
2022-11