8 Malfunctions

8.1

Internal errors

If the display shows "Internal error", the charging station must be disconnected from the mains.
NOTE
For charging systems that are not equipped with a display, the start page of the "DUCTO"
configuration software must be called up for error detection (see chapter 6.3 Configuration of the
charging system with Compleo DUCTO, page 52).
The DUCTO start page displays the status of the charging system and possible error codes in the
event of a fault.
8.2

Residual current circuit breaker (RCCB)

In the event of a residual current, the residual current circuit breaker trips and the charging system is
switched off.
To switch on again, proceed as follows:
1.
Eliminate the cause of the error.
2.
Activate the residual current circuit breaker by pushing up the locking slide on the front of the
housing.
The system starts up.

8.3 Circuit breaker (MCB)

In the event of an overcurrent, the affected circuit breaker trips and the charging system is switched
off.
To switch on again, proceed as follows:
1.
Eliminate the cause of the error.
2.
Reactivate the circuit breaker at the sub-distribution.
The system starts up.