3.3 Technical specifications
General information
Charging system
Article number
Equipment (version
abbreviation)
Charging standard
Connections
Mains connection
Max. connection cross-
1)
section
Ethernet
Min. connection cross-section
Max. length
Ripple control receiver
Max. connection cross-section
Max. length
Electrical characteristics
Mains voltage
Max. rated current
Article number
Mains frequency
Network form
Protection class
Overvoltage category
16
Compleo SOLO advanced
A01Axxxxxx.xx
AV06/ AV19
Mode 3/ IEC 61851
Terminals
rigid: 10 mm²; flexible: 6 mm² (with and without ferrule)
LSA terminals/ RJ45 socket
26 AWG (LSA terminal)
30 m
Contacts for mains-supporting load control (not potential-free/not
galvanically isolated)
1.5 mm²
30 m
230 V/ 400 V
16 A
A01AExxxxx.11
50 Hz
TT/ TN
II
III
A01Axxxxxx.xx | 04
32 A
A01AExxxxx.22
2022-11