9.1.38 PowerMonitoringError (f)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
9.1.39 ADCError (g)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
9.1.40 ShortCircuitError (h)
Name
Area
Description
Reported by:
Handling
Indication on display
Action
90
PowerMonitoringError
Connector
The charging point controller has detected a mains failure.
Connector
•
New charging processes cannot be started
•
The error is shown on the display
f
Check the mains supply.
ADCError
Connector
Internal errors
Connector
•
New charging processes cannot be started
•
The error is shown on the display
g
No action possible by operator. Notify customer service.
ShortCircuitError
Connector
The charging point controller has detected a short circuit between CP and PE.
Connector
•
New charging processes cannot be started
•
The error is shown on the display
h
Switch the complete charging system off and on again. Check the charging
cable for short circuits and/or replace it. To test, start another charging
process with a different vehicle. Notify customer service if the error persists.
A01Axxxxxx.xx | 04
2022-11