3 Installation
3.2

Power Supply

3.2.1 Power Supply Cable Specifications

• Do not solder the ends of wires. Doing so may lead to poor contact.
• When using stranded wire for cabling, make sure that the core is sufficiently twisted. Otherwise, stray wires may cause a
short-circuit with neighboring electrodes.
Item
Cable
Core Length
Tightening Torque

3.2.2 Power Supply Cable Connection

• Electrical shock hazard. Shut the power off before connecting the power supply cable.
• Do not apply an excessive force on the power supply cable. A serious accident may result if the cable disconnects from
the power supply terminal.
Connect the power supply cable to the terminal on the backside of the unit.
Terminal Block Wiring
24VDC
FG
Power
Groundin
Tightening torque
4.43 to 5.31 lbf-in (0.5 to 0.6 N·m)
Notes on the power supply
• The power supply must be used within the allowable range of voltage fluctuation.
• Use a power supply with low noise between cables and between the ground and cables.
• In order to minimize drops in voltage, we recommend to use the thickest power supply cables possible and to twist the cables.
• Keep power supply cables away from high-voltage, large-current carrying cables.
• For use in compliance with UL standards, use a safety extra-low voltage (SELV) power supply for 24 VDC models.
3-4
Solid wire
Stranded wire
Stranded wire with ferrule terminal
(with insulation sleeve)
7mm
4.43 to 5.31 lbf-in (0.5 to 0.6 N·m)
Specifications
2
: 0.2 to 2.5 mm
(AWG24 to AWG14)
2
: 0.2 to 2.5 mm
(AWG24 to AWG14)
2
: 0.25 to 2.5 mm
(AWG22 to AWG14)
Bottom view
Mounting of Terminal Block
Tightening torque
4.43 to 5.31 lbf-in (0.5 to 0.6 N·m)