Error No.
85*
Macro: Undefined system call
90
Unregistered screen library is used.
91
Bitmap data for a switch or lamp is not registered.
94*
Multi-language selection string number error
100
Universal serial: GD-80 compatible entry mode is set.
101
Universal serial: System device memory setting error
132
Ethernet: The connection target is not registered or is
different.
133
Ethernet: IP address No. error
137
The Ethernet port number of the I/F driver is not unique.
140
The I/F driver version of MONITOUCH does not match the
version of the MONITOUCH system program.
143
The device memory map number is not set in the [Logging
Server] window.
155
FROM data unregistered
156
"Backup area" and "station number table" cannot be used at
the same time.
160
The SRAM area size exceeds the available range.
161
The SRAM area is not formatted.
162
Data in the SRAM area does not match the MONITOUCH
system program version.
163
The SRAM/clock setting does not match the SRAM area
format.
192*
I/F driver setting error
196
Data stored in the storage device is different.
301
Recipe setting error
302
The maximum capacity of the alarm server has been
exceeded.
310
An alarm type is not specified for the alarm server.
311
Error among multiple show/hide conditions
400
Vector parts cannot be used because vector rendering is not
allowed.
401
A vector part for a switch or lamp is not registered.
402
Settings that prioritize vector rendering cannot be used
because vector rendering is not allowed.
Contents
Solution
Contact your local distributor.
Check the screen library number.
Check the following points:
No bitmap name is designated.
The part size is too large.
There is no bitmap file in the [Parts] folder located under [MONITOUCH] 
[User].
Contact your local distributor.
Deselect [GD-80 Compatible] from the entry mode part.
Check whether or not access to the outside of the specified device memory
address is attempted, such as by macro indirect designation.
Check the settings in [PLC Table] under [Hardware Setting]  [Target
Settings].
Check the IP address in the network table edit window.
Set a unique port number for the I/F driver.
Update the X1 app version.
If the problem persists, check the editor version and the system program
version of the X1 series unit, and contact your local distributor.
Check the device memory map settings, and set correctly.
The "default.dtm" file has not been transferred although the [Use Internal
Flash ROM as Back-up Area] checkbox is selected in the [System Setting] 
[Unit Setting]  [General Settings] tab window.
Storage destination: C:\MONITOUCH\X1\0\work\extends
As another possibility, no station number table is found although [Yes] is
selected for [Use Port Number Table] under [Communication Setting] in the
[Hardware Setting] window.
[Use Internal Flash ROM as Back-up Area] is selected in the [System Setting]
 [Unit Setting]  [General Settings] tab window although [Yes] is selected
for [Use Port Number Table] under [Communication Setting] in the
[Hardware Setting] window.
It is not possible to use both functions at the same time. Deselect either
function, and transfer the screen program again.
Check the settings in the [System Setting]  [Unit Setting]  [SRAM/Clock
Setting] window.
Format the SRAM area on the SRAM Setting screen in Local mode.
Check the MONITOUCH system program version, and contact your local
distributor.
Format the SRAM area on the SRAM Setting screen in Local mode.
Contact your local distributor.
This error may be relevant to the operation for storing data (screen, 3D
parts, etc.) in a storage device.
Correctly store the data in the X1 storage folder
(C:\MONITOUCH\X1\0\work\strage).
Check the recipe settings.
The specified value is outside the permissible range, or there is a problem
with the record name specification method.
The capacity of DRAM specified under [Internal Storage Setting] in the
[Alarm Server] window has exceeded the maximum available capacity.
Reduce the number set for [Number of Monitoring Alarms] or [Number of
Data to Save].
Check the alarm type setting of monitored alarms for the relevant alarm
block number at [System Setting]  [Alarm Server].
Check the show/hide settings.
Vector rendering is not allowed when the following items are selected at
[System Setting]  [Unit Setting]  [General Setting].
• Retain the previous picture in graphic mode (V8 compatible)
• Drawing process (V8 compatible)
• Draw background when switching screen (V8 compatible)
• XOR drawing of switch/lamp
• Graph drawing (V8 compatible)
Check the settings of the switch or lamp.
Vector rendering of text is not allowed when the following items are
selected at [System Setting]  [Unit Setting]  [General Setting].
• Retain the previous picture in graphic mode (V8 compatible)
• Drawing process (V8 compatible)
• Draw background when switching screen (V8 compatible)
• XOR drawing of switch/lamp
• Graph drawing (V8 compatible)
6.1
Errors
1
2
3
4
5
6
7
8
9
10
6-3

Advertisement

Table of Contents
loading

Table of Contents