Overview; Safety Messages - Emerson Rosemount 3051S Series Reference Manual

Pressure transmitter with foundation fieldbus protocol
Hide thumbs Also See for Rosemount 3051S Series:
Table of Contents

Advertisement

Reference Manual
00809-0200-4801, Rev DA
Section 4
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 51
Safety messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 51
Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 52
Licensing optional blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 52
Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 53
4.1

Overview

This section contains information on operation and maintenance procedures.
Each F
operations. Some hosts will use Device Descriptions (DD) and DD Methods to complete device
configuration and will display data consistently across platforms. The DD can found at
FieldCommGroup.org. There is no requirement that a host or configuration tool support these features.
For DeltaV
describes how to generally use methods. In addition, if host or configuration tool does not support
methods, this section covers manually configuring parameters involved with each method operation.
For more detailed information on the use of methods, see the host or configuration tool manual.
4.2

Safety messages

Procedures and instructions in this section may require special precautions to ensure the safety of the
personnel performing the operations. Information that raises potential safety issues is indicated by a
warning symbol ( ). Refer to the following safety messages before performing an operation preceded
by this symbol.
Explosions can result in death or serious injury.
Do not remove the transmitter covers in explosive environments when the circuit is live.
Transmitter covers must be fully engaged to meet explosion proof requirements.
Before connecting a configuration tool in an explosive atmosphere, make sure the instruments in the
loop are installed in accordance with intrinsically safe or nonincendive field wiring practices.
Electrical shock can result in death or serious injury.
Avoid contact with the leads and terminals. High voltage that may be present on leads can cause
electrical shock.
Performing a 'Restart with defaults' will set all function block information in the device to factory
defaults. This includes the clearing of all function block links and schedule, as well as defaulting all
Resource and Transducer Block user data (Advanced Diagnostic Block algorithm configurations, LCD
Transducer Block parameter configuration, etc.).
Operation and Maintenance
Operation and Maintenance
Fieldbus host or configuration tool has different ways of displaying and performing
OUNDATION
users, the DD can be found at EmersonProcess.com/DeltaV. The information in this section
Operation and Maintenance
October 2016
51