Reference Manual
00809-0200-4801, Rev DA
Table C-1. Resource Block Parameters
Parameter
Index
DEV_REV
12
DD_REV
13
GRANT_DENY
14
HARD_TYPES
15
RESTART
16
FEATURES
17
FEATURE_SEL
18
CYCLE_TYPE
19
CYCLE_SEL
20
MIN_CYCLE_T
21
MEMORY_
22
SIZE
NV_CYCLE_T
23
FREE_SPACE
24
FREE_TIME
25
SHED_RCAS
26
SHED_ROUT
27
200
Valid range
Initial value Units Other Description
23
3
0x0003
1: Run
1
2: Restart
resource
3: Restart with
defaults
4: Restart
processor
See Table 57
0x0C1F
(Bits 0, 1, 2,
3, 4, 10, 11
set)
See Table 57
0
0x0003
0
1760
(55 msec)
set by mfgr
345600000
(180 min.)
0-100%
5.5148
0-100%
0
640000
640000
F
OUNDATION
N/A
Read
Manufacturer revision number associated with the
resource - used by an interface device to locate the DD
Only
file for the resource.
N/A
Read
Revision of the DD associated with the resource - used by
the interface device to locate the DD file for the
Only
resource.
N/A
Options for controlling access of host computer and
local control panels to operating, tuning and alarm
parameters of the block.
N/A
Read
The types of hardware available as channel numbers. See
<Ref 20> The supported hardware types are:
Only
SCALAR_INPUT, SCALAR_OUTPUT
E
Allows a manual restart to be initiated.
N/A
Read
Used to show supported resource block options. See
<Ref 20> The supported features are:
Only
UNICODE_SUPPORT, REPORT_SUPPORT,
FAULT_STATE_SUPPORT, SOFT_WRITE_LOCK_SUPPORT,
HARD_WRITE_LOCK_SUPPORT,
MULTI_BIT_ALARM_SUPPORT, and "restart/relink
required"
N/A
Used to select resource block options. Default selected
option is "restart/relink required"
N/A
Read
Identifies the block execution methods available for this
resource. See <Ref 20> The supported cycle types are:
Only
SCHEDULED, and
COMPLETION_OF_BLOCK_EXECUTION
N/A
Used to select the block execution method for this
resource.
1/32
Read
Time duration of the shortest cycle interval of which the
resource is capable.
millise
Only
c
kbyte
Read
Available configuration memory in the empty resource.
To be checked before attempting a download.
s
Only
1/32
Read
Minimum time interval specified by the manufacturer for
writing copies of NV parameters to non-volatile
millise
Only
memory. Zero means it will never be automatically
c
copied. At the end of NV_CYCLE_T, only those
parameters which have changed need to be updated in
NVRAM.
%
Read
Percent of memory available for further configuration.
Zero in preconfigured resource.
Only
%
Read
Percent of the block processing time that is free to
process additional blocks.
Only
1/32
Time duration at which to give up on computer writes to
function block RCas locations. Shed from RCas will never
millise
happen when SHED_RCAS = 0.
c
1/32
Time duration at which to give up on computer writes to
function block ROut locations. Shed from ROut will
millise
never happen when SHED_ROUT = 0.
c